  i logo! manual a5e00119092-01 welcome to logo! dear customer, we thank you for the purchase of logo! and congratulate you on your decision. with the logo! you have acquired a logic module that meets the stringent quality requirements of iso 9001. logo! can be used in many fields of applications. due to its high functionality and yet easy operation the logo! offers you highly efficient economies for almost any application. logo! documentation this logo! manual contains information relating to the installa- tion, programming and the use of logo! 0ba3 basic devices and logo! 0ba0 expansion modules as well as their down compatibi- lity to the previous basic devices 0ba0, 0ba1 and 0ba2 (0bax are the last four characters of the order number, used to distin- guish the module series). you can find information on wiring the logo! in the logo! ma- nual and in the product info included with every device. find sup- plementary information re programming the logo! with the pc in the online help for logo!soft comfort. logo!soft comfort is the programming software for pcs. it runs under windows  , linux  , and mac os x  and helps you to get familiarized with your logo! and to write, test, print out and ar- chive your programs, independent of the logo! . guide to the manual we have divided this manual into 9 chapters:  working with logo!  installing and wiring the logo!  programming logo!  logo! functions  configuring logo!  logo! program modules  logo! software  applications  appendices
logo! manual a5e00119092-01 ii major changes to previous basic devices (0ba0 to 0ba2)  the design of logo!basic versions is improved: all versions are equipped with 8 inputs and 4 outputs.  logo!basic is modular: all versions are equipped with an ex- pansion interface.  logo! is a versatile equipment: there is a series of expansion modules available to you, including, for example, digital mod- ules and an analog module. new features of the current basic devices (0ba3)  password protection for the user program.  program name.  special 'softkey' function.  new menu item as/w timeo for automatic summertime/winter- time conversion.  acknowledgment of the message text in run mode.  wall mounting is possible. additional support queries related to your logo! can be answered quickly and ea- sily on our website http://www.ad.siemens.de/logo . welcome to logo!
iii logo! manual a5e00119092-01 safety guidelines the notes in this user manual are for your own personal safety and for preventing damage to assets. you should read them care- fully and follow the instructions they give you. these instructions are highlighted by a warning triangle and are marked as follows according to their danger level: ! danger warns that death, serious harm to health or damage to assets will result if the respective precautionary mea- sures are not taken. ! warning warns that death, serious harm to health or damage to can result if the respective precautionary measures are not taken. ! caution warns that harm to health or damage to assets can result if the respective precautionary measures are not taken. note draws your attention to particularly important informa- tion relating to the product and its handling, or to a part of the documentation requiring your special attention. ! warning only skilled personnel should be allowed to start and operate this device. qualified personnel in the sense of the information on safety technology in this manual are persons who are authorized to commission, to ground and to tag circuits, equipment and systems in accor- dance with safety regulations and standards. welcome to logo!
logo! manual a5e00119092-01 iv ! warning this device must always be used as intended for the applications described in the catalog and in the techni- cal specifications, and only in combination with non siemens devices or components approved or recom- mended by siemens . prerequisite for the safe and correct functioning of the product is its proper transportation, storage, commis- sioning and installation as well as meticulous operation and maintenance. copyright  siemens ag 1996 to 2001 all rights reserved the reproduction, distribution or use of this document or its contents is not permitted without express written authority. offenders will be liable for damages. all rights reserved, in particular in the event of patents being granted or the registration of a utility model or design. disclaimer of liability we have examined the contents of this publication for agreement with the hardware and software described. nevertheless, discrepancies cannot be ruled out. any liability and warranty for the accuracy of this information is excluded. the data in this manual are reviewed at regular intervals. any corrections required are included in the subsequent editions. suggestions for improvement are welcomed. welcome to logo!
v logo! manual a5e00119092-01 contents 1 working with logo! 1 . . . . . . . . . . . . . 2 installing and wiring the logo! 11 . . . 2.1 structure of the modular logo! 13 . . . . . . . . . . . . . . . . 2.1.1 maximum structure 13 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.1.2 structure with different voltage classes 14 . . . . . . . . . . . 2.2 installing/uninstalling logo! 15 . . . . . . . . . . . . . . . . . . 2.2.1 profile rail mounting 16 . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.2.2 wall-mounting 20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.3 wiring the logo! 22 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.3.1 connecting the power supply 22 . . . . . . . . . . . . . . . . . . . 2.3.2 connecting logo! inputs connecting 24 . . . . . . . . . . . 2.3.3 logo! outputs connecting 29 . . . . . . . . . . . . . . . . . . . . . 2.4 switching on the logo!/power return 31 . . . . . . . . . . 3 programming logo! 35 . . . . . . . . . . . . . 3.1 connectors 36 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.2 blocks and block numbers 39 . . . . . . . . . . . . . . . . . . . . . 3.3 the way from the circuit diagram to logo! 42 . . . . . 3.4 the 4 golden rules for working with logo! 45 . . . . 3.5 overview of the logo! menus 47 . . . . . . . . . . . . . . . . .
logo! manual a5e00119092-01 vi 3.6 program input and start 48 . . . . . . . . . . . . . . . . . . . . . . . 3.6.1 change to programming mode 48 . . . . . . . . . . . . . . . . . . 3.6.2 first program 49 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.6.3 editing a program 51 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.6.4 assigning a program name 55 . . . . . . . . . . . . . . . . . . . . 3.6.5 password 57 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.6.6 logo! to run mode 61 . . . . . . . . . . . . . . . . . . . . . . . . . . 3.6.7 your second program 63 . . . . . . . . . . . . . . . . . . . . . . . . . 3.6.8 deleting a block 69 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.6.9 deleting multiple interconnected blocks 70 . . . . . . . . . . 3.6.10 correcting typing errors 71 . . . . . . . . . . . . . . . . . . . . . . . 3.6.11 o?o on the display 71 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.6.12 deleting a program 72 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.6.13 summertime/wintertime conversion 73 . . . . . . . . . . . . . 3.7 memory space and size of a circuit 77 . . . . . . . . . . . . . 4 logo! functions 81 . . . . . . . . . . . . . . . . 4.1 constants and connectors co 82 . . . . . . . . . . . . . . . . 4.2 list of basic functions bf 85 . . . . . . . . . . . . . . . . . . . . 4.2.1 and (and) 87 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.2.2 edge-triggered and 87 . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.2.3 nand (and not) 88 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.2.4 nand with edge evaluation 89 . . . . . . . . . . . . . . . . . . . 4.2.5 or (or) 89 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.2.6 nor (or not) 90 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.2.7 xor (exclusive or) 91 . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.2.8 not (negation, inverter) 91 . . . . . . . . . . . . . . . . . . . . . . . contents
vii logo! manual a5e00119092-01 4.3 basics on special functions 92 . . . . . . . . . . . . . . . . . . . . 4.3.1 designation of the inputs 93 . . . . . . . . . . . . . . . . . . . . . . . 4.3.2 time response 94 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.3.3 buffering the clock 95 . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.3.4 retentivity 95 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.3.5 parameter protection 96 . . . . . . . . . . . . . . . . . . . . . . . . . . 4.3.6 gain and offset calculation with analog values 96 . . . 4.4 list of special functions sfr 98 . . . . . . . . . . . . . . . . . 4.4.1 on delay 101 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.4.2 off delay 103 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.4.3 on/off delay 105 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.4.4 retentive on delay 107 . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.4.5 latching relay 109 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.4.6 pulse relay 111 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.4.7 wiping relay pulse output 112 . . . . . . . . . . . . . . . . . . . 4.4.8 edgetriggered wiping relay 114 . . . . . . . . . . . . . . . . . . . 4.4.9 weekly timer switch 115 . . . . . . . . . . . . . . . . . . . . . . . . . . 4.4.10 yearly timer switch 120 . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.4.11 up/down counter 122 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.4.12 operating hours counter 124 . . . . . . . . . . . . . . . . . . . . . . 4.4.13 symmetric clock generator 128 . . . . . . . . . . . . . . . . . . . . 4.4.14 asynchronous pulse generator 130 . . . . . . . . . . . . . . . . . 4.4.15 random generator 131 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.4.16 frequency threshold trigger 133 . . . . . . . . . . . . . . . . . . . 4.4.17 analog threshold switch 135 . . . . . . . . . . . . . . . . . . . . . . . 4.4.18 analog comparator 138 . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.4.19 stairway lighting 141 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.4.20 multifunctional switch 143 . . . . . . . . . . . . . . . . . . . . . . . . . . 4.4.21 message texts 145 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.4.22 softkey 148 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . contents
logo! manual a5e00119092-01 viii 5 configuring logo! 151 . . . . . . . . . . . . . . . 5.1 switching to parameter assignment mode 152 . . . . . . 5.1.1 parameter 153 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.1.2 selecting the parameters 154 . . . . . . . . . . . . . . . . . . . . . . 5.1.3 changing the parameters 155 . . . . . . . . . . . . . . . . . . . . . . 5.2 setting the timeofday and the date (logo! ... c) 158 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 logo! program modules 159 . . . . . . . . . 6.1 overview of the modules 160 . . . . . . . . . . . . . . . . . . . . . . . 6.2 removing and inserting modules 161 . . . . . . . . . . . . . . . 6.3 copying from the logo! to the module 163 . . . . . . . . . 6.4 copying from the module to logo! 165 . . . . . . . . . . . . 7 logo! software 167 . . . . . . . . . . . . . . . . . 7.1 connecting the logo! to a pc 169 . . . . . . . . . . . . . . . . . contents
ix logo! manual a5e00119092-01 8 applications 171 . . . . . . . . . . . . . . . . . . . . . 8.1 staircase or corridor lighting 172 . . . . . . . . . . . . . . . . . . 8.1.1 demands on a staircase lighting system 172 . . . . . . . . 8.1.2 previous solution 172 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.1.3 lighting system with logo! 173 . . . . . . . . . . . . . . . . . . . 8.1.4 special features and expansion options 175 . . . . . . . . . 8.2 automatic door 176 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.2.1 demands on an automatic door 176 . . . . . . . . . . . . . . . . 8.2.2 previous solution 177 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.2.3 door control system with logo! 177 . . . . . . . . . . . . . . . 8.2.4 special features and expansion options 180 . . . . . . . . . 8.2.5 enhanced solutions with logo! 230 rc 180 . . . . . . . . . 8.3 airconditioning system 183 . . . . . . . . . . . . . . . . . . . . . . . 8.3.1 demands on an airconditioning system 183 . . . . . . . . . 8.3.2 advantages of using logo! 186 . . . . . . . . . . . . . . . . . . . 8.4 industrial gate 188 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.4.1 demands on the gate control system 188 . . . . . . . . . . . 8.4.2 previous solution 189 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.4.3 wiring the logo! solution 191 . . . . . . . . . . . . . . . . . . . . . 8.5 centralized control and monitoring of several industrial gates 192 . . . . . . . . . . . . . . . . . . . . . . . . 8.5.1 demands on the gate control system 193 . . . . . . . . . . . 8.6 luminous rows 196 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.6.1 demands on the lighting system 196 . . . . . . . . . . . . . . . 8.6.2 previous solution 197 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.6.3 luminous row control with logo! 230 rc 198 . . . . . . . 8.7 service water pump 200 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.7.1 demands on the control system of a service water pump 201 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.7.2 previous solution 201 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.7.3 service water pump with logo! 230 rc 202 . . . . . . . . . 8.7.4 special features and expansion options 203 . . . . . . . . . 8.8 further application options 204 . . . . . . . . . . . . . . . . . . . contents
logo! manual a5e00119092-01 x a technical data 207 . . . . . . . . . . . . . . . . . . . a.1 general technical data 207 . . . . . . . . . . . . . . . . . . . . . . . . a.2 technical data: logo! 230... and logo! dm8 230r 209 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . a.3 technical data: logo! 24... and logo! dm8 24 212 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . a.4 technical data: logo! 12/24... and logo! dm8 12/24r 215 . . . . . . . . . . . . . . . . . . . . . . . . . . . . a.5 technical data: logo! am 2 218 . . . . . . . . . . . . . . . . . . . a.6 technical data: logo!power 12 v 220 . . . . . . . . . . . . . . a.7 technical data: logo!power 24 v 222 . . . . . . . . . . . . . . a.8 technical data: logo! contact 24/230 224 . . . . . . . . . . b determining the cycle time 225 . . . . . . . c logo! without display 227 . . . . . . . . . . . d logo! menu structure 231 . . . . . . . . . . . . order numbers 235 . . . . . . . . . . . . . . . . . . . . . . abbreviations 237 . . . . . . . . . . . . . . . . . . . . . . . . index 239 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . contents
1 logo! manual a5e00119092-01 1 working with logo! what is logo! ? logo! represents the universal siemens logic module. logo! integrates  controls  an operating and display unit  power supply  interface for expansion modules  an interface for program modules and a pc cable  readytouse basic functions that are often required in daytoday operation, e.g. functions for on/off delays, current impulse relays and softkey  time switch  binary markers  inputs and outputs according to the device type what can logo! do ? logo! offers solutions for domestic and installation engi- neering (e.g. for stairway lighting, external lighting, sun blinds, shutters, shop window lighting etc.), switch cabinet engineering and mechanical and apparatus engineering (e.g. for gate control systems, ventilation systems, or rain- water pumps etc.). logo! can also be implemented for special control sys- tems in conservatories or greenhouses, for control signal processing and, by connecting a communication module (e.g. asi) for distributed local controlling of machines and processes. special versions without operator and display unit are avail- able for series production applications in small machine, apparatus, switch control and installation engineering.
logo! manual a5e00119092-01 2 which new types of equipment are now available? logo! basically, there are two voltage classes:  class 1 < 24 v, that is, 12 v dc, 24 v dc, 24 v ac class 2 > 24 v, that is, 115...240 v ac/dc in versions:  with display : 8 inputs and 4 outputs.  without display : 8 inputs and 4 outputs. each version is integrated in 4 units. it is equipped with an expansion interface and offers you 30 readytous basic and special functions for creating your program. which new expansion modules are now available?  the logo! digital module is available for 12 v dc, 24 v dc and 115...240 v ac/dc, with 4 i/os.  the logo! analog module is available for 12 v dc and 24 v dc, with 2 inputs.  the logo! communication module, e.g. the function module asi (as interface bus system). this module is described in a separate documentation. the digital/analog modules are integrated in 2 units. each one has two expansion interfaces for connecting additional modules. which type of equipment is obsolete?  all versions with 6 inputs.  a long variant with 12 inputs and 8 outputs  the bus version with 12 inputs and 8 outputs. the modular strikers of logo! replace this type of equip- ment. it's your choice the different basic versions and expansion modules offer structures and precise adaptation to you specific tasks. logo! provides solutions ranging from the small domestic installation through small automation tasks to extensive tasks integrating a bus system (e.g. the as interface). working with logo!
3 logo! manual a5e00119092-01 note every basic logo! unit can be expanded with expansion modules of the same voltage class. mechanical encoding (pin in the housing) prevents interconnection of devices of different voltage classes. exception : the left interface of the analog module or communication module is separated from potential. this means that these expansion modules can be con- nected to devices of a different voltage class. see also chapter 2.1 'structure of the modular logo!'. regardless of the number of modules connected to the logo!, the following i/o and memory bits are available: i1 to i24, ai1 to ai8, q1 to q16 and m1 to m8. working with logo!
logo! manual a5e00119092-01 4 how the logo! is structured logo! basic (e.g.: 230 rc) 1 2 3 i7 i8 q1 q2 q3 q4 4 35 72 l1 n 4 90 55 logo! expansion module (e.g.: dm8 230r) 4 module slot with cover 5 6 status display run/ stop control panel (not with rco) lcd (not with rco) i5 i6 i2 i3 i4 i1 q3 q4 q1 q2 35 l1 n i2 i3 i4 i1 36 run/stop 90 53 7 8 mechanical coding pins 3 1 2 9 9 10 9 expansion interface 1 2 3 outputs power supply inputs 8 8 8 10 mechanical coding sockets 10 11 11 slide 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 5 6 7 4 working with logo!
5 logo! manual a5e00119092-01 logo! basic (e.g.: 12/24 rc) 1 2 3 i7 i8 q1 q2 q3 q4 4 35 72 l+ m 4 6 5 90 55 logo! expansion module (e.g.: dm8 12/24r) 4 module slot with cover 5 6 status display run/ stop control panel (not with rco) lcd (not with rco) i5 i6 i2 i3 i4 i1 q3 q4 q1 q2 35 l+ m i2 i3 i4 i1 36 run/stop 90 53 7 8 mechanical coding pins 3 1 2 7 9 9 10 9 expansion interface 1 2 3 outputs power supply inputs 1 2 1 2 1 2 1 2 8 8 8 10 mechanical coding sockets 10 11 11 slide 1 2 1 2 1 2 1 2 4 working with logo!
logo! manual a5e00119092-01 6 status display run/ stop i1 pe input 2x(0..10v/0..20 ma) 35 l+ m 36 run/stop 90 53 7 8 mechanical coding pins 1 7 9 9 10 9 expansion interface 1 2 power supply inputs 8 8 10 mechanical coding sockets logo! am2 11 11 slide m1 u1 m2 u2 i2 grounding terminal for connecting ground and shielding of the analog measuring line. 12 12 4 l+ m 2 working with logo!
7 logo! manual a5e00119092-01 how to recognize which logo! model you have the logo! identifier informs of various properties:  12: 12 v dc version  24: 24 v dc version  230: 115...240 v ac version  r: relay outputs (without r: transistor outputs)  c: integrated weekly timer switch  o: version without display  dm: digital module  am: analog module  fm: function module (e.g. asi) symbols variants with display are equipped with 8 inputs and 4 out- puts variants without display are equipped with 8 inputs and 4 outputs the digital module is equipped with 4 digital inputs and 4 digital outputs the analog module is equipped with 2 analog inputs function module (e.g. asi) with 4 virtual inputs and 4 virtual outputs working with logo! +
logo! manual a5e00119092-01 8 variants logo! is available in the following variants: sym- bol designation supply voltage inputs outputs properties logo! 12/24rc 12/24 v dc 8 digital* 4 relays 230 v x 10 a logo! 24 24 v dc 8 digital* 4 transistor 24 v x 0.3 a no clock logo! 24rc 24 v ac 8 digital 4 relays 230 vx10 a logo! 230rc # 115...240 v ac/dc 8 digital 4 relays 230 vx10 a logo! 12/24rco 12/24 v dc 8 digital* 4 relays 230 vx10 a no display no keyboard logo! 24rco 24 v ac 8 digital 4 relays 230 vx10 a no display no keyboard logo! 230rco # 115...240 v ac/dc 8 digital 4 relays 230 vx10 a no display no keyboard *: alternatively, 2 analog inputs (0...10v) and 2 fast inputs can be used. #: 230 v ac variants: inputs in two groups of 4. within a group only the same phase, between groups different phases are possible. expansion module the logo! can be connected to the following expansion modules: symbol designation supply voltage inputs outputs logo! dm 8 12/24 r 12/24 v dc 4 digital 4 relays (3) logo! dm 8 24 24 v dc 4 digital 4 transistors logo! dm 8 230r 115...240 v ac/dc 4 digital (1) 4 relays (3) logo! am 2 12/24 v dc 2 analog 010 v or 020 ma (2) none (1): no different phases allowed within the inputs. (2): 010 v, 020 ma connection is optional. (3): the maximum sum switching power across all four relays is 20 a. working with logo!
9 logo! manual a5e00119092-01 certification, recognition and approval logo! is certified according to ul, csa and fm.  ul listing mark underwriters laboratories (ul) to ul 508 standard, file no. 116536  csacertificationmark canadian standard association (csa) to standard c22.2 no. 142, file no. lr 48323  fm certification factory mutual (fm) approval to standard class number 3611, class i, division 2, group a, b, c, d class i, zone 2, group iic ! warning personal injury and material damage may be incurred. in potentially explosive areas, personal injury or property damage can result if you withdraw any connectors while the system is in operation. always switch off the power supply for the logo! and its components before you discon- nect any connectors. logo! carries ce marking, complies with vde 0631 and iec 611312 standard and has interference suppression to en 55011 (limit class b, class a for asi bus operation). shipbuilding certification has been requested.  abs american bureau of shipping  bv bureau veritas  dnv det norske veritas  gl germanischer lloyd  lrs lloyds register of shipping  prs polski rejestr statkw working with logo!
logo! manual a5e00119092-01 10 logo! can therefore be used both in industry and domes- tic areas. c tick mark (australia) the products carrying the label shown at the side are com- pliant with as/nzl 2064:1997 (class a) standard working with logo!
11 logo! manual a5e00119092-01 2 installing and wiring the logo! general guidelines when mounting and wiring your logo! you should ob- serve the following guidelines:  when wiring the logo! ensure you are conforming with current rules and standards. you should also heed any national and regional regulations when installing and operating the devices. contact the relevant authorities to find out the standards and regulations that apply in your specific case.  use wires with the appropriate crosssection for the amount of current involved. logo! can be wired using cables with a conductor crosssection of 1.5 mm 2 and 2.5 m m2 , refer to chapter 2.3.  don't screw the connectors too tightly. maximum torque: 0.5 n/m, refer to chapter 2.3.  keep wiring distances as short as possible. if longer wires are necessary, a shielded cable should be used. arrange you wires in pairs: one neutral conductor with one phase conductor or one signal line.  keep separate: ac circuits highvoltage dc circuits with fast switching cycles low voltage signal wiring.  ensure that the wires have the required strain relief.  provide suitable overvoltage protection for wires that could be vulnerable to lightning.
logo! manual a5e00119092-01 12  do not connect an external power supply to an output load parallel to a dc output. this can result in reverse current at the output unless you have a diode or a simi- lar block in your configuration. note logo! must always be mounted and wired by skilled per- sonnel who are familiar and follow the general rules of the technology and the respective current rules and standards. installin g and wirin g the logo!
13 logo! manual a5e00119092-01 2.1 structure of the modular logo! 2.1.1 maximum structure maximum structure logo! with analog inputs (logo! 12/24 rc/rco and logo! 24) logo! basic, 4 digital modules and 3 analog modules logo! basic logo! dm8 logo! dm8 logo! dm8 logo! dm8 logo! am2 logo! am2 logo! am2 i9...i12 i13...i16 i17...i20 i21...i24 ai3 , ai4 ai5 , ai6 ai7 , ai8 i1......i6 ai1 , ai2 tip when using inputs i7 / ai1 and i8 / ai2 as analog inputs, that is, ai1 and ai2, you should avoid to use them as digital inputs i7/i8 also . maximum structure of logo! without analog inputs (logo! 24 rc/rco and logo! 230 rc/rco) logo! basic, 4 digital modules and 4 analog modules logo! basic logo! dm8 logo! dm8 logo! dm8 logo! dm8 logo! am2 logo! am2 logo! am2 i9...i12 i13...i16 i17...i20 i21...i24 ai3 , ai4 ai5 , ai6 ai7 , ai8 i1 . . . . . . . . . . . i8 ai1 , ai2 logo! am2 fast/optimal communication in order to achieve an optimal and fast communication be- tween logo! basic and the various modules, we recom- mend the structure adigital modules first, then the analog moduleso (example above). installin g and wirin g the logo!
logo! manual a5e00119092-01 14 2.1.2 structure with different voltage classes since the potential of the left analog module interface (am2, 12/24 v dc) is separated from the right one, you can connect it to all logo! basic versions. the potential of expansion modules arranged to the right of the analog module is separated from logo! basic. it is therefore possible to connect an expansion module of a different voltage class as logo! basic at the right side of an analog module. example: logo! 230 ... logo! dm8 230r logo! dm8 12/24 r logo! dm8 24 logo! am2 logo! am2 the potential of an analog module is separated logo! am2 logo! dm8 24 installin g and wirin g the logo!
15 logo! manual a5e00119092-01 2.2 installing/uninstalling logo! dimensions logo!'s installation dimensions are compliant with din 43880. logo! can be snapmounted on a 35 mm din en 50022 profile rail or mounted on the wall. width of logo!:  logo! basic has a width of 72 mm, corresponding to 4 unit segments.  the width of logo! expansion modules is 36 mm, cor- responding to 2 unit segments. note we shall illustrate mounting and removal in a graphic over- view for a logo! 230 rc and a digital module. the shown methods also apply for all other logo! basic vari- ants and expansion modules. ! warning expansion modules must only be aextractedo and apluggedo after power is switched off. installin g and wirin g the logo!
logo! manual a5e00119092-01 16 2.2.1 profile rail mounting installing this is how you mount a logo! basic and a digital mod- ule on a profile rail: logo! basic: 1. place the logo! basic onto the rail and 2. then swing it around on the rail. the mounting slide at the rear must be engaged 1 2 3 4 5 6 logo! digital module: 3. at the right side of the logo! basic/logo! expansion module, remove the cover of the connector 4. place the digital module to the right of the logo! basic 5. slide the digital module towards the left up to the logo! basic installin g and wirin g the logo!
17 logo! manual a5e00119092-01 6. using a screwdriver, slide the integrated to the left. in it end position the slide engages in the logo! basic. repeat steps 3 to 6 is you want to install additional expan- sion modules. note the expansion interface of the last expansion module must be covered. installin g and wirin g the logo!
logo! manual a5e00119092-01 18 uninstalling to uninstall logo!, proceed as follows: ....... if only one logo! basic is mounted: part a 1. insert a screwdriver into the hole shown at the lower end of the mounting slide and push it downward 2. swing the logo! basic off the profile rail. 1 2 1 2 3 4 ab installin g and wirin g the logo!
19 logo! manual a5e00119092-01 ....... in case there is at least one expansion module connected to the logo! basic: part b 1. using a screwdriver, push down the slide and slide it to the right 2. slide the expansion module towards the right and 3. insert a screwdriver into the hole shown at the lower end of the mounting slide and push it downward 4. swing the expansion module off the profile rail. repeat steps 1 to 4 for all other expansion modules. note if more than one expansion module is connected, start with the last module at the right. make sure that the slide of the module to be installed/re- moved is not connected to the next module. installin g and wirin g the logo!
logo! manual a5e00119092-01 20 2.2.2 wallmounting before you wallmount the device, the mounting slides at the rear of the device must be pushed towards the outside or the inside. insert the upper mounting slide (included with the modules) and push the lower one to the outside. you can the fasten the logo! with two  4mm screws (tight- ening torque 0.8 to 1.2 n/m) to the bracket to mount it on the wall. mounting slides installin g and wirin g the logo!
21 logo! manual a5e00119092-01 drilling template for wallmounting before you mount the logo! to the wall you should pre- pare the drill holes with the help of this template. screw bore  4 mm tightening torque 0.8 to 1.2 n/m logo! basic logo! expansion module 1 2 1 2 all dimensions in mm 2 2 n x 35,5 +/0,2 53,5 +/0,2 35,5 +/0,2 98 +/0,3 installin g and wirin g the logo!
logo! manual a5e00119092-01 22 2.3 wiring the logo! wire the logo! using a screwdriver with a 3 mm blade. you don't need wire ferrules for the connectors. you can use wires up to the following sizes:  1 x 2.5 mm 2  2 x 1.5 mm 2 for each second connector compartment connecting torque: 0.4...0.5 n/m or 3...4 lbin note ensuring that the connectors are covered. to protect the logo! adequately against contact to voltage carrying parts, country specific standards must be conformed with. 2.3.1 connecting the power supply logo! the 230 v versions are suitable for nominal line voltages oft 115 v ac/dc and 240 v ac/dc. logo! the 24 v and 12 v versions are suitable for a supply voltage of 24 v dc, 24 v ac or 12 v dc. note the information on connection in the product information document shipped with your device and the technical specifications in appen- dix a relating to permissible voltage tolerances, line fre- quency and current consumption. note power failure might result for instance in an additional edge after power restoration with edgetriggered special functions. data of the last uninterrupted cycle are stored in logo!. installin g and wirin g the logo!
23 logo! manual a5e00119092-01 connecting this is how you connect your logo! to the power supply: l1 l+ n m logo! ..... with dc supply voltage logo! ..... with ac supply voltage protection by fuse if required (recommended) for: 12/24 rc...: 0.8 a 24: 2.0 a with voltage peaks, use a varistor (mov) with at least 20% higher op- erating voltage than nominal voltage. m l+ i1 i2 i3 i4 i5 i1 i2 i3 i4 l1 n note logo! has protective insulation. a ground terminal is not necessary. protective circuit with ac voltage you can eliminate line voltage peaks with a metal oxide varistor (mov). make sure the operating voltage of the va- ristor exceeds the rated voltage by at least 20% (e.g. s10k275) installin g and wirin g the logo!
logo! manual a5e00119092-01 24 2.3.2 connecting logo! inputs connecting prerequisites connect sensors to the inputs. sensors may be: pushbut- tons, switches, photoelectric barriers, daylight control switches etc. sensor attributes for logo! logo! 12/24 rc/rco logo! dm8 12/24 r logo! 24 logo! dm8 24 i1 ... i6 i7, i8 i1 ... i6 i7, i8 circuit state 0 < 5 v dc < 5 v dc < 5 v dc < 5 v dc input current < 1.0 ma < 0.05 ma < 1.0 ma < 0.05 ma circuit state 1 >8 v dc >8 v dc >8 v dc >8 v dc input current > 1.5 ma > 0.1 ma > 1.5 ma > 0.1 ma logo! 24 rc/rco (ac) logo! 230 rc/rco (ac) logo! dm8 230 r (ac) logo! 230 rc/rco (dc) logo! dm8 230 r (dc) circuit state 0 < 5 v ac < 40 v ac < 30 v dc input current < 1.0 ma < 0.03 ma < 0.03 ma circuit state 1 > 12 v ac > 79 v ac > 79 v dc input current > 2.5 ma > 0.08 ma > 0.08 ma installin g and wirin g the logo!
25 logo! manual a5e00119092-01 note the digital inputs of the logo! 230 rc/rco are divided into two groups equipped with 4 inputs each. within a group all inputs must be operated on the same phase. dif- ferent phases are only possible between the groups. example: i1 to i4 on phase l1 , i5 to i8 on phase l2 . within the input circuit of the logo! dm8 230r you must not connect different phases. sensor connections connecting glow lamps, 2wire bero to the logo! 230 rc/230 rco or logo! dm8 230 r (ac) l1 n n l1 c 3sb14303c 3sb14203d 3tx74623t order number for c: siemens switching devices & sys- tems restrictions circuit status transition 0  1 / 1  0 when the circuit state changes from 0 to 1, circuit state 1 and, in the case of a change from 1 to 0, circuit state 0 must be in place for at least one program cycle for logo! to recognize the new circuit status. the cycle time of the program processing depends on the size of the program. in chapter 3.7 you can find a descrip- tion of a short test program that will help you to work out the current cycle time. installin g and wirin g the logo!
logo! manual a5e00119092-01 26 special features of logo! 12/24 rc/rco and logo! 24  fast inputs: i5 and i6 these versions are also equipped with inputs for frequency functions. the same restrictions do not apply to these fast inputs. note there are no changes in the standard version compared to previous basic devices (0ba0 to 0ba2): i5 and i6 are still the fast inputs, that is, no changes are necessary to trans- fer the program written in these versions to the new 0ba3 devices. in contrast, programs written in a logo!...l ver- sion (fast inputs i11/i12) must be changed. expansion modules do not have fast inputs.  analog inputs: i7 and i8 with the logo! 12/24 rc/rco and logo! 24 versions the inputs i7 and i8 can be used as normal digital inputs or as analog inputs. how the input is used depends on its pur- pose in the logo! control program. you can use the digital capability of the input with i7/i8 and its analog capability with the identifiers ai1 and ai2. see also section 4.1. note the expansion module logo! am2 is available for addi- tional inputs. for the analog signals you must always use twisted and shielded cables as short as possible. installin g and wirin g the logo!
27 logo! manual a5e00119092-01 sensor connections this is how to connect sensors to the logo! : logo! 12/24 .... l+ m the inputs of these devices are nonisolated and therefore require the same reference potential (ground) as the power supply. with the logo! 12/24 rc/rco and logo! 24 you can tap the analog signal between the supply voltage and ground. m l+ i1 i2 i3 i4 i5 i8 logo! 230 .... l1 n l3 l2 the inputs of these de- vices are arranged in 2 groups with 4 inputs each. different phases are only possible between, but not within the blocks. n l1 i1 i2 i3 i4 i5 i6 ! warning current safety regulations (vde 0110, ... and iec 611312, ... as well as ul and csa) do not permit the connection of different phases to one input group (i1i4 or i5i8) of an ac version or on the inputs of one digital module. installin g and wirin g the logo!
logo! manual a5e00119092-01 28 logo! am2 current mea- surement voltage measure- ment m l+ l+ m current u1 i2 m2 u2 i1 m1 pe l+ m measuring current 020 ma 1 2 1 pe ground cable shielding grounding terminal for connecting ground and shieldin g of the analog mea- suring line 3 3 profile rail run/stop 2 m m l+ installin g and wirin g the logo!
29 logo! manual a5e00119092-01 2.3.3 logo! outputs connecting logo! ...r... the logo! outputs ... r ... are relays. the relay contacts are isolated from the power supply and from the inputs. prerequisites for relay outputs you can connect different loads to the outputs such as lamps, fluorescent tubes, motors, contactors etc. the loads connected to logo! ...r... must have the following proper- ties:  the maximum switched current depends on the type of load and the number of switching cycles (for details refer to chapter a atechnical datao ).  logo! basic...r..: in switched on state (q = 1) and with ohmic load the maximum current is 10 a and for inductive loads the maximum is 3 a (2 a at 12/24 v ac/ dc).  logo! dm8....r properties are identical to logo! ba- sic...r, with the following restrictions: the maximum sum switching power across all four relays is 20 a. connecting this is how to connect the load to the logo! ... r ... an: protection with automatic circuit breaker (max. 16 a, b16, e.g. power circuit breaker 5sx2 116-6 (if desired) dm8...r 1 2 q1 q2 1 2 q5 q6 1 2 1 2 load load installin g and wirin g the logo!
logo! manual a5e00119092-01 30 logo! with transistor outputs logo! variants with transistor outputs can be identified by the fact that the letter r is missing from their type designa- tion. the outputs are short circuitproof and overload proof. an auxiliary load voltage supply is not necessary since logo! supplies the load voltage. prerequisites for transistor outputs the load connected to logo! must have the following properties:  the maximum switched current is 0.3 amperes per out- put. connecting this is how to connect the load to a logo! with transistor outputs: load: 24 v dc, 0.3 a max. dm8...24 q1 q2 mm q5 q6 mm load load installin g and wirin g the logo!
31 logo! manual a5e00119092-01 2.4 switching on the logo!/power return logo! does not have a power switch. the reaction of logo! when switched on depends  whether a program is stored logo! in logo!,  whether a program module is connected,  whether it is a logo! version without display (logo!...rco),  in which state logo! was prior to poweroff and  whether a pc cord was connected. the logo! reaction to all possible situations is described on the following page: installin g and wirin g the logo!
logo! manual a5e00119092-01 32 06.21.01 mo 09:00 >program.. pc/card.. clock.. start with stored program from logo! & b01 q1 no program in memory (empty) (with program) or logo! in run state (empty) (with program) or program in memory (empty) or with program copied from the module to the logo! before power off after power on (with program) with stored program from logo! with program copied from the module to the logo! 06.21.01 mo 09:00 06.21.01 mo 09:00 i : 0. , 1. , 2. 123456789 0123456789 01234 q : 0. , 1. 123456789 0123456 b03:par cnt = 0028 par = 0300 ...... ...... i : 0. , 1. , 2. 123456789 0123456789 01234 i : 0. , 1. , 2. 123456789 0123456789 01234 >program.. pc/card.. clock.. start >program.. pc/card.. clock.. start no program press esc logo! in run state pc  = logo! stop? press esc no program press esc no program in memory & b01 q1 program in memory no program press esc or and pc cord installin g and wirin g the logo!
33 logo! manual a5e00119092-01 you can also try to remember the 4 simple rules for starting logo! basic: 1. if there is no program in logo! or in the connected program modules, logo! (with display) reports: 'no program press esc'. 2. if there is a program on the program module, it is auto- matically copied to logo! . a program in logo! is overwritten. 3. if there is a program in logo! or in the connected pro- gram module, logo! takes over the operate state it had prior to poweroff. the version without display (logo! ...rco) is switched automatically from stop to run mode (led toggles from red to green). 4. if at least on function is switched retentive or if you have used a function that is permanently retentive the current values are also retentive at poweroff. note if a power loss occurs while you are entering a program, the program in logo! is deleted after power is returned. you should therefore save your original program before changing it on a program module (card) or on a computer (logo!soft comfort). installin g and wirin g the logo!
logo! manual a5e00119092-01 34 logo! basic operating states logo! basic knows tow operate states: stop and run stop run  display: 'no program' (not logo! ...rco)  logo! to programming mode (not logo! ...rco)  the led lights up red (only logo! ...rco)  display: screen form for monitoring i/o and mes- sages (after start in the main menu) (not logo! ...rco)  logo! to programming mode (not logo! ...rco)  the led lights up green (logo! ...rco) action by logo!:  the inputs are not read.  the program is not exe- cuted.  the relay contacts are al- ways open or the transistor outputs are switched off action by logo!:  logo! reads the state of the inputs  logo! calculates the state of the outputs with the pro- gram.  logo! switches the relays/ transistor outputs on or off logo! expansion modules, operating state logo! expansion modules know three operating states: the led is lit green, red or orange. led is lit green (run) red (stop) orange the expansion module communi- cates with the left device the expansion module does not communicate with the left device initialization phase of the expansion module installin g and wirin g the logo!
35 logo! manual a5e00119092-01 3 programming logo! your first steps with logo! the term programming refers to the input of a circuit pro- gram. a logo! program is actually no more than a circuit diagram presented in a slightly different form! we have adapted this presentation to the logo! display. in this chapter we are going to show you how to transform your applications into a logo! program. note the logo! versions logo! 12/24 rco, logo! 24 rco and logo! 230 rco do not have a keyboard or a display unit. they are mainly intended for series production ap- plications in small machine and plant engineering. logo!...rco versions are not programmed locally. rather, programs in logo!soft comfort or in the memory modules of other logo! units are transferred to this de- vice. in the first section of this chapter we shall use a small ex- ample to show you how to handle the logo! .  we shall begin by introducing two basic terms, namely the connector and the block , and show you what they represent.  in a second step, we shall work out a simple and com- mon circuit program that you ...  can enter directly in logo! in the third step. only few manual pages later you are going to have your first running program stored in the logo! . with a suitable hardware (switches etc.) you will then be able to carry out your first tests.
logo! manual a5e00119092-01 36 3.1 connectors logo! has i/os example of a configuration with several modules: l+ m i13i14i15i16 q11 q9 q12 q10 run/stop l+ m a!3 run/stop l+mi1i2 i3i4i5i6 q1 q2 q3 q4 inputs outputs ai1 ai2 l+ m i9 i10i11i12 q7 q5 q8 q6 run/stop m3u3ai4m4u4 analog inputs 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 pe input 2x (..10v/..20 ma) l+ m each input is identified by the letter i and a number. when you look at the logo! from the front, you can see the con- nectors for the inputs at the top. only the analog module logo! am2 has its inputs at the bottom. each output is identified by the letter q and a suffix. you can see that the connectors of the outputs are located at the bottom. pro g rammin g logo!
37 logo! manual a5e00119092-01 note logo! can recognize, read and switch the i/o of all ex- pansion slots, regardless of their type. the i/o is shown in the order of the module arrangement. the following i/os and memory bits are available for pro- gramming: i1 to i24, ai1 to ai8, q1 to q16 and m1 to m8. for the logo! 12/24... and logo! 24 inputs i7 and i8 applies: if ix is used in the program, the input signal is in- terpreted as digital signal; with aix it is an analog signal. input aix can only be the connector that is actually capa- ble of carrying an analog signal. pro g rammin g logo!
logo! manual a5e00119092-01 38 logo!'s connectors the term connector refers to all connections and states in logo! . the i/o status can be '0' or '1'. status '0' means that the input does not carry a voltage. status '1' means that the input carries voltage. but that, we assume, is nothing new to you. we have implemented the connectors hi, lo and x in order to facilitate programming for you: the default fixed status of 'hi' (high) is '1' and of 'lo' (low) it is '0'. if you do not want to wire the input of a block, use the 'x' connector. the meaning of the term block is explained on the next page. logo! knows the following connectors: connec- tors logo! basic dm am inputs logo! 230 rc/rco logo! 24 rc/rco two groups: i1... i4 and i5 ... i8 i9 ... i24 ai1(ai3) ... ai8 logo! 12/24 rc/ rco logo! 24 i1... i8 along with i7(ai1), i8(ai2) outputs q1...q4 q5 ... q16 none lo signal with '0' level (off) hi signal with '1' level (on) x an existing connection that is not used dm : digital module. am : analog module. pro g rammin g logo!
39 logo! manual a5e00119092-01 3.2 blocks and block numbers this chapter shows you how to use the logo! elements to create extensive circuits and how the blocks and the i/o are interconnected. for this purpose, please turn to section 3.3. there you are going to learn how to convert a common circuit into a logo! program. blocks a block in logo! is a function that is used to convert input information into output information. previously you had to wire up the individual elements in the control cabinet or terminal box. when you program logo!, you connect connectors with blocks. to do this, simply select the connection you require from the co menu we have used the abbreviation co for the english term oconnectoro to name the menu. logic operations the most elementary blocks are logical links:  and  or  ... i 1 i 2 x  1 inputs i1 and i2 are connected to the or block. the last input of the block is not used and is therefore marked with an x. q the special functions are far more powerful:  pulse relay  counter  on delay  softkey  .... chapter 4 provides a complete list of logo!'s functions. pro g rammin g logo!
logo! manual a5e00119092-01 40 displaying a block in logo! the figure below shows a typical logo! display. only one block can be displayed at a time. we have therefore introduced block numbers to help you check the circuit structure. b02  1 i2 q1 b01 display view of logo! x block number assigned by logo! here is another block connected input this connection is not required output block assigning a block number when you insert a block in a program, logo! always as- signs it a block number. logo! uses the block numbers to show you the block in- terconnections. primarily, the block numbers are meant to help you find your way around the program. i1 i2 i3  1 b01 b02 b02  1 b03 q1 b01 b01 moving around the program using the key i4 i5 i6  1 b01 these blocks are interconnected block numbers q1 x b03 pro g rammin g logo!
41 logo! manual a5e00119092-01 the overview shows you three displays of logo!, which together form the program. you can see how logo! inter- connects the blocks, using the block numbers. advantages of the block numbers you can append almost any block to an input of the current block using its block number. in this way you can reuse the interim results of logical links or other operations. this saves you input work and memory space, and ensures a clear arrangement of your circuit. in this case, you must know how logo! has named the blocks. note for efficient working, we recommend that you create block diagram of the program. this is going to make pro- gramming easier for you, because here you can enter the block numbers assigned by logo!. if you program the logo! using the logo!soft comfort software, you can directly create a logic diagram of your program. pro g rammin g logo!
logo! manual a5e00119092-01 42 3.3 the way from the circuit diagram to logo! how a circuit is represented in a circuit diagram you know, of course, how a circuit is represented in a cir- cuit diagram. nevertheless, here is an example: k1 s1 k1 s2 e1 the load e1 is switched on and off by means of the switches (s1 or s2) and s3. the relay k1 picks up if s1 or s2 and s3 are closed. s3 realizing this circuit with logo! in logo! you construct a circuit by interconnecting blocks and connectors: s1 ... s3 wiring of the inputs i3 x q1 &  1 i1 i2 x program in logo! wiring of the outputs l1 n to convert a circuit in logo!, start at the output of the cir- cuit. the output is the load or the relay that is to be switched. pro g rammin g logo!
43 logo! manual a5e00119092-01 convert the circuit to blocks. to do this, go through the cir- cuit from the output to the input: step 1 : at output q1 there is a series connection of the normally open contact s3 with another circuit component. the series connection corresponds to an and block: i3 x q1 & step 2 : s1 and s2 are connected in parallel. the parallel circuit corresponds to an or block: i3 x q1 &  1 i1 i2 x you have now completely described the circuit for the logo! . now connect the i/os to the logo! . wiring connect the switches s1 to s3 to the screw terminals of the logo! :  connect s1 to connector i1 on the logo!  connect s2 to connector i2 of the logo!  connect s3 to connector i3 of the logo! since only two inputs of the or blocks are being used, the third input of this block must be marked as aunusedo. this is indicated using the suffix x . likewise, only 2 inputs of the and block are used. thus, the third input is also marked as 'unused' by the suffix x . the output of the and block controls the relay of output q1. the load e1 is connected to output q1. pro g rammin g logo!
logo! manual a5e00119092-01 44 wiring example the following table shows you the wiring based on a 230 v ac version of logo!. l1 n wiring of the inputs output wiring s3 s2 s1 l1 n n l1 i1 i2 i3 i4 1 2 q1 last pro g rammin g logo!
45 logo! manual a5e00119092-01 3.4 the 4 golden rules for working with logo! rule 1 changing operating mode  edit the circuit in programming mode. after power on and if ano program, press esco is displayed, you can open the programming mode by pressing the esc key.  you can edit the time and parameter values of an exist- ing program in the parameter assignment mode and in programming mode .  start run mode by executing 'start' in the main menu.  in run mode you can return to parameter assign- ment mode via esc key.  if you want to return from parameter assignment mode to programming mode , execute the astopo command in the parameter assignment menu. when prompted to confirm with ayeso when astop prgo ap- pears, move the cursor to a yes o and confirm with ok . you can find more information on operating modes in the chapter logo! menu structure page 231. rule 2 outputs and inputs  always program a circuit working from the output to- wards the input.  you can connect an output to several inputs, however, you cannot fan out one input to several outputs.  you cannot connect an output to a preceding input in the same program path. for such internal recursions you should interconnect memory bits or outputs. pro g rammin g logo!
logo! manual a5e00119092-01 46 rule 3 cursor and cursor movement when programming a circuit, note:  when the cursor appears in the form of an underscore, you can move the cursor : use the , , or key to move the cursor in the circuit press ok to change to oselect terminal/blocko press esc to exit circuit programming.  when the cursor appears as solid square, you should select a connector/block use the or key to select a connector/block. confirm your selection with ok. press esc to go back one step. rule 4 planning  make a complete plan of your circuit on paper before you input the circuit or program logo! directly using logo!soft or logo!soft comfort.  logo! can only save complete programs. if the circuit program is incomplete logo! cannot exit the program- ming mode . pro g rammin g logo!
47 logo! manual a5e00119092-01 3.5 overview of the logo! menus >program.. pc/card.. clock.. start >edit prg prg name clear prg password >pc
card card main menu programming menu transfer menu >stop set param set clock prg name ok ok esc esc parameter assignment menu programming mode parameter assignment mode = logo! >set clock s/w time menu clock esc ok you can find more information on menus in the chapter logo! menu structure page 231. pro g rammin g logo!
logo! manual a5e00119092-01 48 3.6 program input and start you have designed a circuit and now want to enter it in logo! . a small example will show how to do this. 3.6.1 change to programming mode you have connected the logo! to the power supply and voltage is switched on. the display shows you the mes- sage: no program press esc switch the logo! to programming mode by pressing the esc key. this will take you to the main menu of the logo!: >program.. pc/card.. clock.. start logo!'s main menu the first character in the first row is o>o. use the keys and to move the o>o up and down. move the o>o to opro- gram..o and confirm with ok . logo! opens the program- ming menu. >edit prg prg name clear prg password logo!'s programming menu pro g rammin g logo!
49 logo! manual a5e00119092-01 here too, you can move the o>o by pressing the and keys. move the o>o to o edit prg o (edit program, that is, in- put) and confirm with ok . logo! no shows you the first output: logo!'s first output q1 you are now in programming mode. use the keys and keys to select the other outputs. at this point you can start programming your circuit. note since our program has not yet been saved with a pass- word in logo! you can start editing your program right away. if you start a program already saved with password protection, aedit prga and confirmation with ok would be followed by the prompt to enter a password. in this case you cannot start editing unless you enter the correct pass- word. (refer to chapter 3.6.5.) 3.6.2 first program let us now take a look at the following parallel circuit con- sisting of two switches. circuit diagram how the circuit is represented in a circuit diagram k1 s1 k1 s2 e1 the load is switched on via switch s1 or s2. logo! in- terprets the circuit as 'or', because either switch s1 or s2 switches the output. pro g rammin g logo!
logo! manual a5e00119092-01 50 translated in the logo! program this means: relay k1 (in logo! via output q1) is controlled by an or block. program i1 and i2 are connected to the input of the or block, whereby s1 is connected to i1 and s2 to i2. this is what the logo! program then looks like: i1 i2 x q1  1 wiring the corresponding wiring: l1 n i4 i5 i6 i7 i8 q1 q2 q3 q4 l1 n s1 s2 l n i1 i1 i3 i1 i1 i1 i1 i1 i2 1 2 1 2 1 2 1 2 switch s1 acts on input i1, switch s2 on input i2. the load is connected to relay q1. pro g rammin g logo!
51 logo! manual a5e00119092-01 3.6.3 editing a program let us now edit the program (working from the output to the input). initially, logo! displays the output: logo!'s first output q1 the q of q1 is underscored. this underscore is called the cursor . the cursor indicates your current position in the program. you can move the cursor by pressing the , , and keys. now press the key. the cursor moves to the left. the cursor indicates your position in the program. q1 at this point, enter only the first block (the or block). press ok to switch to editing mode. the cursor is displayed as a solid square: you can now select a terminal or a block q1 co the cursor no longer appears in the form of an underscore; but rather as a flashing solid square. at the same time logo! gives you various options. select the bf (basic functions) by pressing the key until bf appears. confirm with ok . logo! then displays the first block in the list of basic functions: pro g rammin g logo!
logo! manual a5e00119092-01 52 an and is the first block in the list of basic functions. the cursor is dis- played as solid square, thus prompting you to select a block. & b01 q1 now press the or key until the or block is displayed:  1 b01 q1 the cursor square is still positioned in the block. press ok to confirm your selection.  1 the is what you see in the display b01 q1 b01  1 q1 your entire program looks like this block number you have now entered the first block. each block you enter is assigned a block number. what is now left to do is to wire the inputs of the block. this is how it is done: press ok .  1 the is what you see in the display b01 q1 co pro g rammin g logo!
53 logo! manual a5e00119092-01 select the co list: confirm with ok  1 the is what you see in the display b01 q1 x the first element in the co list is the oinput not usedo char- acter, an ' x' . use the keys or to select input i1. note use the key  to go to the start of the co list: i1, i2 .... to lo, and again ' x '. use the  key to start at the end of the co list: lo, hi, q ..... to i1, and once again ' x '.  1 q1 i1 b01 press ok . i1 is now connected to the input of the or block. the cursor jumps to the next input of the or block.  1 the is what you see in the display b01 q1  1 q1 up to this point, your program in logo! looks like this i1 i1 b01 pro g rammin g logo!
logo! manual a5e00119092-01 54 now connect input i2 to the input of the or block. you al- ready know how to do this: 1. switch to editing mode: ok 2. select the co list: per or 3. accept the co list: ok 4. select i2: per or 5. accept i2: ok i2 is now connected to the input of the or block:  1 the is what you see in the display b01 q1  1 q1 i1 i1 b01 i2 i2 up to this point, your program in logo! looks like this we do not need the last input of the or block for this pro- gram. in a logo! program the unused inputs are identified with an oxo. now enter the 'x': 1. switch to editing mode: ok 2. select the co list: per or 3. accept the co list: ok 4. select x: per or 5. accept x: ok now all the inputs of the block are now wired. logo! con- siders the program as being complete logo! jumps back to output q1. the is what you see in the display  1 q1 your program looks like this i1 b01 i2 q1 b01 x if you want to review your first program, you can use the or key to move the cursor through the program. pro g rammin g logo!
55 logo! manual a5e00119092-01 but we are going to exit program input now. this is how it is done: 1. return to the programming menu: esc if this does not return you to the programming menu, you have not wired a block completely. logo! indicates posi- tions at which you have missed something (logo! accepts only complete programs, for the sake of your safety.). also refer to page 71. note logo! has now saved your program retentive on power failure. the program is only stored in the logo! until you delete it per instruction. 3.6.4 assigning a program name you can assign a name to your program. this name con- sists of upper/lower case letters, numbers and special characters. the maximum length is 16 characters. 2. move a>o to ' prg name ': per or 3. accept 'prg name': ok use the keys and you can list the alphabet from a(a) to z(z), numbers and special characters. you can also list them forward and backward. here you can select any let- ter, number or character. input an empty by moving the cursor with to the next position. this is the first character of the list. examples: press once: the result is an a a o press four times: the result is a left bracket a { oetc. pro g rammin g logo!
logo! manual a5e00119092-01 56 this character set is available: a b c f g h i j k l m n o p q r s t u v w x y z a b c d e f g h i j k l m n o p q r s t u v w x y z 0 1 2 3 4 5 6 7 8 9 ! o # $ % & ' ( ) * + , . / : ; < = > ? @ [ \ ] ^ _ ` { | } ~ let us assume you want to name your program a abc o: 4. select a a o: press 5. to the next letter: press 6. select a b o: press 7. to the next letter: press 8. select a c o: press 9. confirm the complete name: ok your program is now named a abc o and you have been returned to the programming menu. the program name can be changed in the same way as above. note the program name can only be changed in programming mode. you can read the program name in programming mode and in parameter assignment mode . pro g rammin g logo!
57 logo! manual a5e00119092-01 3.6.5 password you can assign a password in to protect it from being edited by unauthorized persons. how to assign a password the maximum password length is 10 characters. it consists of uppercase letters only (a to z). on the device you can only assign, edit and deactivate the password in the apasswordo menu. in the programing menu: 1. move '>' to ' password ': per or 2. accept the 'password': ok use the keys or to move up and down the alphabet to select your letters. since logo! allows only uppercase letters for the password, you can quickly access the letters oat the endo of the alphabet faster by using the key : press once gives you a a z o pressing twice gives you a a y o etc. let us now assign the password a aa o to our first program. the display shows: old: no password new: the procedure is the same as for entering the program name. under anewo, enter: 3. select a a o: press 4. to the next letter: press 5. select a a o: press pro g rammin g logo!
logo! manual a5e00119092-01 58 the display now shows: old: no password new: 6. confirm the password: ok your program is now password protected with a aa o and you have been returned to the programming menu. note if the input of the new password is interrupted with esc logo! returns to the programming menu without saving the password. you can also input your password in logo!soft comfort. you can only upload a password protected program in logo!soft comfort or edit your program on the device after you have entered the correct password. changing the password in order to change the password you must know the cur- rent one. in the programming menu: 1. move '>' to 'password': per or 2. accept the 'password': ok under aoldo, enter your old password (in our case ' aa ') by repeating steps 3 to 6 as described above. pro g rammin g logo!
59 logo! manual a5e00119092-01 the display now shows: old: aa new: now you can enter a new password under anewo, e.g. a zz o: 3. select a z o: press 4. to the next letter: press 5. select a z o: press the display now shows: old: aa new: z z 6. confirm your new password: ok a zz o is now your new password and you are back in the programming menu. deactivating the password let us assume you want to deactivate the password for whichever reason. for example, you want to grant another user read/write access to your program. same as when changing it, you must know your current password (in our example a zz o). in the programming menu: 1. move '>' to 'password': per or 2. accept the 'password': ok under aoldo you must now enter your current password as described in steps 3 to 5. confirm your entry with ok . pro g rammin g logo!
logo! manual a5e00119092-01 60 the display shows: old: zz new: now deactivate the password without making another entry : 3. confirm the aemptyo password: ok the password does not exist anymore. you have been re- turned to the programming menu. note this deactivation switches off the password prompt. edit- ing is possible without entering a password. for the moment, leave the password prompt deactivated in order to speed up our progress with the remaining tuto- rials/examples. password: wrong input ! when you enter the wrong password and confirm your entry with ok , logo! does not open editing mode, but rather returns to the programming menu. this repeats itself over and over until you have entered the correct password. pro g rammin g logo!
61 logo! manual a5e00119092-01 3.6.6 logo! to run mode logo! to run mode in the main menu. 1. return to the main menu: esc 2. move '>' to ' start ': per or 3. confirm 'start': ok logo! starts the program and displays: display field of the logo! in run mode status of the inputs date and current timeofday (only applies to ver- sions with clock) status of the outputs i:0.,1.,2. 123456789 0123456789 01234 06.21.01 mo 09:00 q:0.,1. press press press press 123456789 0123456 date and tod on the display this display flashes as long as date and tod are not set. presentation of the inputs on the display inputs i1 to i9 i:0.,1.,2. 123456789 0123456789 01234 inputs i20 to i24 inputs i10 to i19 presentation of the outputs on the display q:0.,1. 123456789 0123456 outputs q1 to q9 outputs q10 to q16 pro g rammin g logo!
logo! manual a5e00119092-01 62 what does ologo! is in runo mean? in run mode logo! processes the program. to do this, logo! initially reads the status of the inputs, determines the status of the outputs using your specified program and switches the outputs on or off. the logo! presents the i/o status in this way: input/output has the state '1': inverse input/output has the state '0': not inverse i:0.,1.,2. 123456789 0123456789 01234 q:0.,1. 123456789 0123456 in this example, only the inputs i1, i15, q8 and q12 are ahigha. status display l1 n s1 s2 =1 when switch s1 is closed, voltage is applied to input i1, which has the state '1'. logo! uses the program to calculate the output states. output q1 has the state '1' here. if the status of q1 is '1' logo! switches the relay q1; the load on q1 is sup- plied with voltage. i1 i2 q1 i:0.,1.,2. 123456789 0123456789 01234 q:0.,1. 123456789 0123456 let us examine this, using our example: pro g rammin g logo!
63 logo! manual a5e00119092-01 3.6.7 your second program now that you have successfully programmed your first cir- cuit ( plus the program name and, if desired, assigned a password), we shall commence by showing in this section how you can modify existing programs and use the special functions. in a second program you are shown how to:  insert a block in an existing program.  select a block for a special function.  assign parameters. modification of circuits in order to produce the second program, we are now going to modify the first one slightly. in the first step, let us examine the circuit diagram for the second program: l1 n s1 s2 you already know the first part of the circuit. switches s1 and s2 op- erate a relay. this relay switches on the load e1. it should switch off the load again on expiration of a 12minute off delay. k1 k1 e1 in logo! :  1 q1 i1 i2 x x t this is the new block you will recognize the or block and the output relay q1 from or first program. only the off delay is new. pro g rammin g logo!
logo! manual a5e00119092-01 64 how to edit the program switch the logo! to programming mode as a reminder, this is how it was done: 1. switch the logo! to programming mode (in run mode: press esc . this opens the parameter assignment menu select 'stop' : confirm with ok, move '>' to 'yes' and confirm once again with ok ). see page 45 2. in the main menu, select oprogram..o 3. in the programming menu, select oedit prgo (if required, enter the password and confirm with ok ) you can now modify the existing program. how to insert a new block in a program move the cursor underneath the b in b01 (b01 is the block number of the or): q1 b01 move the cursor: press the key we now insert the new block at this position. press ok . q1 bn logo! shows you the bn list. select the sf list (  key): q1 sf the sf list contains the blocks for the special functions. confirm with ok. pro g rammin g logo!
65 logo! manual a5e00119092-01 the block of the first special function is displayed: trg t q1 when you select a special or basic function block, logo! displays the respective function block. the full square cursor is positioned in the block. use the keys  or  to select the required block. select the block (off delay, see next diagram) and confirm with ok : r the inserted block is assigned the block number b02. block b01, up to now con- nected to q1, is automatically connected to the upper input of the new block. the cursor is positioned at the upper input of the new block. b01 t q1 b02 'ok' is here preceded with trg the offdelay block has three inputs. the upper input is the trigger input (trg). use this input to start the off delay. in our example, the off delay is started via the or block b01. reset the time and outputs, using the reset input. in the t parameter, set off delay time. in our example, we do not use the reset input of the off delay. we wire it with 'x'. in the first program you have seen how this is done. as a reminder to you: 1. position the cursor under the r:per or 2. change over to editing mode: ok 3. select the co list: per or 4. accept the co list: ok 5. select x: per or 6. accept x: ok x b01 t q1 b02 the display should now look like this: pro g rammin g logo!
logo! manual a5e00119092-01 66 how to assign block parameters now, specify the off delay time t: 1. if the cursor is not yet positioned underneath the t, move it there: per or 2. change over to editing mode: ok for the parameters logo! displays the parameter assign- ment screen form: b02: the t parameter of block b02: is a time + means: the parameter is displayed and can be edited in parameter assignment mode b02:t t=00.00s+ time value time unit the cursor is positioned on the first digit of the time value. this is how you change the time value:  use the keys and to move the cursor to and fro.  use the keys and to change the value.  confirm the time value you have entered with ok . setting the time set the time t = 12:00 minutes: 1. move the cursor to the first digit: per or 2. select the digit '1': per or 3. shift the cursor to the second digit: per or 4. select the digit '2': per or 5. move the cursor onto the unit: per or 6. select the m unit for minutes: per or pro g rammin g logo!
67 logo! manual a5e00119092-01 displaying/hiding parameters type of protection if you do not want to have the parameter displayed in pa- rameter assignment mode: 1. move the cursor onto the type of protection: per or 2. select the type of protection '': per or on the display you should now see: b02:t t=12:00m+ b02:t t = 12:00m or type of protection + : the time t can be changed in parameter assignment mode type of protection : the time t cannot be changed in parameter assignment mode 3. close and confirm your entries with ok note you can only change the type of protection and the time unit in programming mode, that is, you cannot do this in parameter assignment mode. checking the program this program path for q1 is now complete. logo! shows you the output q1. you can review the program on the dis- play. use the keys to browse through the program, e.g. or to move from block to block and to move between the inputs on a block. pro g rammin g logo!
logo! manual a5e00119092-01 68 exiting programming mode you already know how to exit a program from our first pro- gram. as a reminder: 1. return to the programming menu: esc 2. return to the main menu: esc 3. move '>' to 'start': per or 4. confirm 'start': ok logo! has now returned to run mode: you can use or for viewing and monitoring the status of i/os. 06.21.01 th 09:30 pro g rammin g logo!
69 logo! manual a5e00119092-01 3.6.8 deleting a block let us assume, in your program you want to delete block b02 and connect b01 directly to q. q1 i1 i2 x x t b01 b02 proceed as follows: 1. switch the logo! to programming mode (as a reminder, refer to page 45). 2. select 'edit prg': per or 3. confirm 'edit prg': ok (if required, enter the password and confirm with ok ) 4. position the cursor on the input of q1, that is, under- neath b02. use the : b02 q1 5. 6. confirm with ok. 7. now, replace the block b02 with block b01 directly on output q1. how to do this: select the bn list: per or accept the bn list: ok select 'b01': per or accept 'b01': ok result: block b02 is deleted because it is not used in the circuit. block b01 is now connected directly to the output instead of b02. pro g rammin g logo!
logo! manual a5e00119092-01 70 3.6.9 deleting multiple interconnected blocks in the following program, (corresponds with the program in chapter 3.6.7) let us assume you want to delete the blocks b01 and b02. q1 i1 i2 x x t b01 b02 proceed as follows: 1. switch the logo! to programming mode (as a reminder, refer to page 45). 2. select 'edit prg' : per or 3. confirm 'edit prg': with ok (if required, enter the password and confirm with ok ) 4. position the cursor on the input of q1, that is, under- neath b02. use the : b02 q1 5. confirm with ok. 6. now, replace block b02 with the connector x on output q1. how to do this: select the co list: per or accept the co list: ok select x: per or accept x: ok pro g rammin g logo!
71 logo! manual a5e00119092-01 result: block b02 is deleted because it is not used in the circuit. all blocks connected to b02 are deleted (e.g. in our example block b01). 3.6.10 correcting typing errors programming errors can be corrected easily in logo! :  provided editing mode is not yet closed, you can revert by one step via esc .  if you have configured all inputs, just enter the wrong input once again: 1. move the cursor to the location of the error. 2. change to editing mode. confirm with ok 3. enter the correct input circuit. you can only replace one block with another if the new block has exactly the same number of inputs as the old one. however, you can delete the old block and insert a new one. you can choose any new block. 3.6.11 o?o on the display if you have entered a program and want to exit aedit prgo with esc , logo! checks whether you have connected the inputs of all blocks. if you have missed out on an input or parameter logo! leads you to the respective position. it indicates the first faulty position and marks all inputs which are not connected and the parameters with a question mark. r ? in this position you have con- nected the input b01 t ? q1 b02 you have not yet declared a parameter value connect the input and enter a value for the parameter. you can then close the editor via esc key. pro g rammin g logo!
logo! manual a5e00119092-01 72 3.6.12 deleting a program this is how you delete a program: 1. switch the logo! to programming mode >program.. pc/card.. clock.. start logo! displays the main menu 2. in the main menu, use or to move '>' to 'pro- gram..' confirm with ok >edit prg prg name clear prg password logo! opens the programming menu. 3. move '>' to ' clear prg ': per or 4. confirm 'clear prg': ok clear prg >no yes to prevent you from unintentionally de- leting your program, we have imple- mented an additional prompt. if you do not want to delete the program, leave the '>' on 'no' and confirm with ok . if you are sure that you want to delete the program saved in the logo!, 5. move the '>' to 'yes': per or 6. confirm with ok . logo! deletes the program. pro g rammin g logo!
73 logo! manual a5e00119092-01 3.6.13 summertime/wintertime conversion you can enable or disable automatic summertime/winter- time conversion in programming mode under the menu item aclocko. 1. switch the logo! to programming mode 2. you are now in the main menu and want to select the menu item 'clock': per or 3. confirm 'clock': ok 4. move the '>' to 's/w time': per or 5. confirm 's/w time': ok logo! displays: >on off s/w time off the current setting of automatic summertime/wintertime conversion is shown in the bottom row. factory default is off ('off': disabled). enabling summertime/wintertime conversion you now want to enable this conversion and specify or de- clare its parameter: 1. move '>' to 'on': per or 2. confirm 'on': ok the display shows: >eu uk us .. pro g rammin g logo!
logo! manual a5e00119092-01 74 description of what is displayed:  ' eu ' represents the start and end of summertime in europe.  ' uk ' represents the start and end of summertime in the united kingdom.  ' us ' represents the start and end of summertime in the united states.  . . : here you can specify any month, day and time dif- ference. the default program for eu, uk and us conversion are found in the table below: start of summertime end of summertime time difference d eu last sunday in march: 02:00>03:00 fourth sunday in octo- ber: 03:00>02:00 60 min uk last sunday in march: 02:00>03:00 last sunday in octo- ber: 03:00>02:00 60 min us first sunday in april: 02:00>03:00 last sunday in octo- ber: 03:00>02:00 60 min . . customizing the month and the day: 02:00> 02:00 + time difference customizing the month and the day: 03:00> 03:00 + time difference specified by the user (minute ac- curacy) note you can specify a time difference d between 0 and 180 minutes. let us assume you want to enable european summertime/ wintertime conversion: 3. move '>' to 'eu': per or 4. confirm 'eu': ok pro g rammin g logo!
75 logo! manual a5e00119092-01 logo! displays: >on off s/w time on eu logo! indicates that european summertime/wintertime conversion is enabled. how to customize parameters if all parameters/conversions do not apply to your country, you can customize them in the menu item ' . . '. how to do this: 1. confirm '> on' once again: ok 2. move '>' to ' . . ': per or 3. confirm menu item ' . . ' : ok the display shows: mm.dd + : 01.01 : 01.01  =000 min month (mm) and day (dd) start of summertime end of summertime the desired time difference in min- utes 0 cursor / full square let us assume you want to configure the following parame- ters: start of summertime 31st of march, end of summer- time 1st of november, time difference of 120 minutes. this is how you can enter your data:  use the keys and to move the cursor/full square to and fro.  use the keys and to change the values at the cur- sor position. pro g rammin g logo!
logo! manual a5e00119092-01 76 the display shows: 0 31. march 1. november time difference of 120 min mm.dd + : 03.31 : 11.01  =120 min  confirm all your entries with ok . you have now customized your summertime/wintertime conversion. logo! displays: >on off s/w time on .. logo! indicates that summertime/wintertime conversion is enabled and that the parameters were customized ( '..' ). note to disable summertime/wintertime conversion, all you have to do is to confirm 'off' with ok in this menu pro g rammin g logo!
77 logo! manual a5e00119092-01 3.7 memory space and size of a circuit then size of a program (circuit program in logo!, circuit diagram) is limited by the available memory space (memory requirement for the blocks). memory area in logo! you can only utilize a specific number of blocks in your program. some blocks require extra memory for their special functions. the memory required for special functions can be split into four memory areas.  par : the area in which the logo! stores setpoint val- ues, e.g. the limit values of a counter.  ram : the area in which the logo! stores actual val- ues, e.g. a counter value.  timer : the area logo! utilizes for timer functions, e.g. for on delays.  rem : the area in which the logo! stores retentive actual values, e.g. the hours counter value. in blocks with selective use of the retentivity function, this memory area is only used if retentivity is switched on. resources available in logo! a program in logo! can occupy the following maximum resources: blocks par ram timer rem bit 56 48 27 16 15 8 logo! monitors memory utilization. it restricts the func- tions offered in the function lists to those for which suffi- cient memory space is physically available. pro g rammin g logo!
logo! manual a5e00119092-01 78 memory utilization the table gives you an overview of the specific memory requirements of the special functions: function block par ram timer rem latching relay* 0 (1) 0 (1) pulse relay* 0 (1) 0 (1) wiping relay 1 1 1 0 edgetriggered wiping relay 1 1 1 0 on delay 1 1 1 0 off delay 2 1 1 0 on/off delay 2 1 1 0 retentive on delay 2 1 1 0 weekly timer switch 6 2 0 0 yearly timer switch 2 0 0 0 up/down counter* 2 (2) 0 (2) operating hours counter 2 0 0 4 symmetric clock generator 1 1 1 0 asynchronous pulse genera- tor 3 1 1 0 random generator 2 1 1 0 frequency trigger 3 3 1 0 analog trigger 4 2 0 0 analog comparator 3 4 0 0 staircase lighting switch 1 1 1 0 comfort switch 2 1 1 0 message texts 1 0 0 0 softkey 1 (1) 0 (1) pro g rammin g logo!
79 logo! manual a5e00119092-01 * depending whether or not the function is configured re- tentive, it occupies the following memory space:  retentivity switched off: ram area  retentivity switched on: rem area utilization of memory space if you are unable to add another block when editing a pro- gram, this is a clear indication that no more memory space is available. logo! offers only the blocks for which it can provide sufficient memory space. if a block from the list cannot be added into the logo! program you cannot call this list anymore. if the memory space is fully utilized you must optimize your circuit program or use a second logo! . determining the amount of memory required when calculating the memory requirements of a circuit, you must always take all memory areas into account. example: q1 x i2 b01 b02 b03 x b04 00 0 0 60 0 2 no 1 no 2 no 3 i1 t b05 b06 t q2 i3 i4 x par ram rem timer par ram rem timer pro g rammin g logo!
logo! manual a5e00119092-01 80 the sample program contains: block function memory area no. par ram timer rem blocks b01 or 0 0 0 0 1 b02 and 0 0 0 0 1 b03 timer switch 6 2 0 0 1 b04 on delay 1 1 1 0 1 b05 clock generator 1 1 1 0 1 b06 and 0 0 0 0 1 resources occupied by the program 8 4 2 0 6 memory limitations in logo! 48 27 16 15 56 in logo! still available 40 23 14 15 50 the program therefore fits into logo!. pro g rammin g logo!
81 logo! manual a5e00119092-01 4 logo! functions order logo! provides various elements for the programming mode. in order to avoid loosing the overview, we have dis- tributed the elements in 'lists'. these lists are:   co : connector list (connector) (see chapter 4.1)   bf : list of basic functions and, or, ... (refer to chapter 4.2)   sf : list of special functions (refer to chapter 4.4)   bn : list of reusable blocks configured in the circuit program list contents all lists show the elements available in logo!. normally, this includes all connectors, all basic functions and all spe- cial functions the logo! knows. this includes all blocks you have created in logo! by the time you call the list  bn . if not all is shown logo! does not show all elements if:  no more blocks can be added in this case, there is either no more memory space available or the maximum possible number of blocks was reached (56).  a specific block's memory space requirement would exceed the space available in logo! .
logo! manual a5e00119092-01 82 4.1 constants and connectors co constants and connectors ( = co) are inputs, outputs, memory bits and fixed voltage levels (constants). inputs: 1) digital inputs digital inputs are designated with an i . the numbers of the digital inputs (i1, i2, ...) correspond with the numbers of the input connectors of the logo! basic and of the connected digital modules in the order they were installed. see the figure on the next page. 2) analog inputs the logo! versions logo! 24, logo! 12/24 rc and logo! 12/24 rco are equipped with the inputs i7 and i8 which can also be used as ai1 and ai2, depending on the program. if these inputs are used as i7 and i8 the input signal is interpreted as digital value. when using ai1 and ai2 the signals are interpreted as analog value. when you connect an analog module, the inputs are numbered in the order of the existing analog inputs. when selecting the in- put signal in programming mode, only the analog inputs ai1 to ai8 are offered for special functions which sensibly ought to be connected to analog inputs. see the figure on the next page. outputs outputs are designated with a q . the numbers of the out- puts (q1, q2, ...) correspond to those of the of the output connectors of the logo! basic and of the connected ex- pansion modules in the order they were installed. see the figure on the following page. logo! functions
83 logo! manual a5e00119092-01 l+ m i13i14i15i16 q11 q9 q12 q10 run/stop l+ m a!3 run/stop l+mi1i2 i3i4i5i6 q1 q2 q3 q4 inputs outputs ai1 ai2 l+ m i9 i10i11i12 q7 q5 q8 q6 run/stop m3u3ai4m4u4 analog inputs 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 pe input 2x (..10v/..20 ma) l+ m memory bits memory bits are identified with an m . memory bits are virtual outputs, with a value at their output analog to that at the input. the logo! provides 8 memory bits, namely m1 ... m8. tip on previous devices with previous versions of logo! the maximum number of blocks connected in series can be exceeded by adding memory bits to the program. initialization memory bit memory bit m8 is set during the first cycle of the user pro- gram. you can therefore use it in the program as initializa- tion memory bit. after the first program cycle it is automati- cally reset. in all subsequent cycles you can use memory bit 8 in the same way as memory bits m1 to m7 for setting, deleting and evaluation operations. note the output signal of the memory bit is always that of the previous program cycle. the value does not change within the same program cycle. logo! functions
logo! manual a5e00119092-01 84 levels voltage levels are designated hi and lo . a constant block status of a1o = hi or a0o = lo is achieved via input of a fixed level or constant hi or lo value. open connectors block pins not connected are symbolized with an x . logo! functions
85 logo! manual a5e00119092-01 4.2 list of basic functions bf basic functions represent a simple boolean algebra logic. when programming a circuit, you can find the basic func- tion blocks in the bf list. in the last column you can locate the position of every basic function by scrolling through the bf list per  key from top to bottom. here are the avail- able basic functions: view in the circuit diagram view in logo! designation of the basic function posi- tion in the bf series circuit n.o. contact and (see page 87) 1 and with edge trig- gering (see page 87) 7 parallel circuit n.c. contact nand (and not) (see page 88) 4 nand with edge triggering (see page 89) 8 parallel circuit n.o. contact or (see page 87) 2 logo! functions
logo! manual a5e00119092-01 86 view in the circuit diagram posi- tion in the bf designation of the basic function view in logo! series circuit n.c. contact nor (or not) (see page 90) 5 double change- over contact xor (exclusive or) (see page 91) 6 n.c. con- tact not (negation, inverter) (see page 91) 3 logo! functions
87 logo! manual a5e00119092-01 4.2.1 and (and) series connection of multiple make contacts in the circuit dia- gram: symbol in logo!: the status of the and output is 1 when all inputs are 1, that is, if they are closed. the status of a block input pin which is not connected (x) is: x = 1. table of the and logic 123q 0 0 0 0 0010 0100 0110 1000 1010 1100 1111 4.2.2 edgetriggered and symbol in logo!: the output status of an edgetriggered and is only 1 if all inputs are 1, and if at least one input was 0 in the previous cycle. the status of a block input pin which is not connected (x) is: x = 1. logo! functions
logo! manual a5e00119092-01 88 timing profile for the edgetriggered and 1 cycle 3 q 2 123456789 1 0 4.2.3 nand (and not) parallel connection of multiple break contacts in the circuit diagram: symbol in logo!: the output status of the nand is only 0 if all inputs are 1, that is, if the contacts are closed. the status of a block input pin which is not connected (x) is: x = 1. table of the nand logic 123q 0 0 0 1 0011 0101 0111 1001 1011 1101 1110 logo! functions
89 logo! manual a5e00119092-01 4.2.4 nand with edge evaluation symbol in logo!: the output status of the nand with edge evaluation is only 1 if at least one input is 0 and if all inputs were 1 in the previous cycle. the status of a block input pin which is not connected (x) is: x = 1. timing profile for the nand with edge evaluation 1 cycle 3 q 2 123456789 1 0 4.2.5 or (or) the parallel connection of multiple make contacts in a circuit diagram: symbol in logo!: the output status of the or is only 1 if at least one input is 1, that is, if one of the contacts is closed. the status of a block input pin which is not connected (x) is: x = 0. logo! functions
logo! manual a5e00119092-01 90 table of the or logic 123q 0 0 0 0 0011 0101 0111 1001 1011 1101 1111 4.2.6 nor (or not) the series connection of multiple break contacts in the circuit diagram: symbol in logo!: the output status of the nor is only 1 if all inputs are 0, that is, if switched off. the nor output is set to 0 at the 0 to 1 transition at one of the inputs. the status of a block input pin which is not connected (x) is: x = 0. table of the nor logic 123q 0 0 0 1 0010 0100 0110 1000 1010 1100 1110 logo! functions
91 logo! manual a5e00119092-01 4.2.7 xor (exclusive or) the xor in the circuit diagram as 2 changeover contacts connected in series: symbol in logo!: the output status of the xor is 1 if the inputs are non- equivalent . the status of a block input pin which is not connected (x) is: x = 0. table of the xor logic 12q 0 0 0 011 101 110 4.2.8 not (negation, inverter) a break contact in the circuit diagram: symbol in logo!: the output status is 1 if the input is 0. the not block is an input status inverter. the advantage of the not is, for example: for the logo! you do not need break contacts anymore. you simply use a make contact and convert it with the not into a break con- tact. table of the not logic 1q 0 1 10 logo! functions
logo! manual a5e00119092-01 92 4.3 basics on special functions at first sight, the special functions differ from the basic functions because of their different input designation. spe- cial functions include timer functions, retentivity and diverse parameter assignment options for customizing the pro- gram. in this section we should like to give you a brief overview of the input designations and of special basics relating to spe- cial functions. the special functions in particular are de- scribed in chapter 4.4. logo! functions
93 logo! manual a5e00119092-01 4.3.1 designation of the inputs logical inputs here you find the description of the connections which can be linked to other modules or inputs of the logo! device.  s (set): input s can be used to set the output to a1o.  r (reset): the reset input r has priority over all other inputs; it switches the outputs to a0o.  trg (trigger): this input is used to trigger the start of a function cycle.  cnt (count): this input is used to capture count pulses.  fre (frequency): frequency signals to be evaluated are input with this designation.  dir (direction): this input, for example, determines the direction of count.  en (enable): this input enables the block functions. when this input is a0o, the block ignores all other signals.  inv (invert): the output signal of the block is inverted when this input is set.  ral (reset all): all internal values are reset. connection x at the inputs of the special functions the inputs of the special functions are 0 when connected to the connection oxo. that is, the inputs are 'lo'. logo! functions
logo! manual a5e00119092-01 94 parameter inputs to some of the inputs you do not apply signals, but rather assign specific values to the function block.  par (parameter): this input is not wired. here, you configure the block parameters.  t (time): this input is not wired. here you configure the times for a block.  no (cam): this input is not wired. here, you configure the time pat- terns.  p (priority): this input is not wired. here, you specify priorities and determine whether or not a message must be acknowl- edged in run mode. 4.3.2 time response parameter t with some of the special functions it is possible to config- ure a time value t. when specifying the time, please note that the values to be entered depend on the set timebase: timebase _ _ : _ _ s (seconds) seconds : 1 / 100 seconds m (minutes) minutes : seconds h (hours) hours : minutes b01:t t=04.10h+ setting the time t to 250 minutes: unit in hours h: 04.00 hours 240 minutes 00.10 hours +10 minutes = 250 minutes logo! functions
95 logo! manual a5e00119092-01 note always specify a time t  0.10 s. the time t is not de- fined for t = 0.05 s and t= 0.00 s. accuracy of t all electronic components have slightly different parame- ters. this can cause deviations in the configured time t. with the logo! the maximum deviation is  0.02 %. if 0.02 % of time t is smaller than 0.1 seconds the maxi- mum deviation is 0.1 seconds. example: the maximum deviation for 1 hour (3600 seconds) is  0.02 %, that is,  0.72 seconds. the maximum deviation for 1 minute (60 seconds) is  0.1 seconds. timer switch accuracy in order to prevent inaccuracies of clock timing in the c versions as a result of this deviation, the timer switch is continuously compared with a highly accurate timebase and readjusted. this results in a maximum timing deviation of  5 s/day. 4.3.3 buffering the clock the internal clock of a logo! continuous operation even on power failure, that is, the clock is buffered. the duration of this buffering is influenced by the ambient temperature. at an ambient temperature of 25 c the buffering time is normally 80 hours. 4.3.4 retentivity for special functions there is a possibility to keep circuit states and counter values retentive. this, however, re- quires that retentivity is enabled for the respective func- tions. an exception is the principally retentive operating hours meter. see also chapter 6.1 on the description of modules. logo! functions
logo! manual a5e00119092-01 96 4.3.5 parameter protection in the parameter protection configuration you can specify whether the parameters can be displayed and edited in logo! parameter assignment mode . there are two op- tional configurations: +: the parameter configuration can be displayed and edited in parameter assignment mode, too. : the parameter configuration cannot be displayed in pa- rameter assignment mode. editing is only possible in pro- gramming mode. see the example on page 67. 4.3.6 gain and offset calculation with analog val- ues the gain and offset parameters can be used to adjust the internal image of an analog value to the actual measure- ment value. characteristic quantity minimum maximum terminal voltage (in v) 0 10 internal value 0 1000 gain (in %) 0 1000 offset 999 +999 the terminal voltage (at input ai) of 0 to 10 v is mapped internally to values from 0 to 1000. a terminal voltage higher than 10 v is mapped internally by the value 1000. with the gain parameter, for example, you can achieve an amplification of 1:10 at a setting of 1000 %. the offset parameter can be used to shift the zero of mea- surement values. formula displayed value ax = (internal value + offset)  gain / 100 the gain value displayed is the amplification as %age. hence, the division by 100 in the formula. logo! functions
97 logo! manual a5e00119092-01 example of analog values mea- sure- ment value voltage (v) internal value offset gain dis- played value (ax) 0 5 10 0 500 1000 0 0 0 1 1 1 0 5 10 0 5 10 0 500 1000 0 0 0 100 100 100 0 500 1000 0 5 10 0 500 1000 0 0 0 1000 1000 1000 0 5000 10000 0 5 10 0 500 1000 500 500 500 1 1 1 5 10 15 0 5 10 0 500 1000 500 500 500 100 100 100 500 1000 1500 0 5 10 0 500 1000 200 200 200 100 100 100 200 300 800 0 10 0 1000 999 999 1000 1000 9990 19990 0,02 0,02 0,02 0,02 2 2 2 2 0 0 0 0 1 10 100 1000 0 0 2 20 30 c 0 c +70 c 0 3 10 0 300 1000 300 300 300 10 10 10 30 0 70 you can find an a sample application in the description of the special function aanalog comparatoro on page 138. for information on analog inputs also refer to chapter 4.1. logo! functions
logo! manual a5e00119092-01 98 4.4 list of special functions sfr when programming in logo!, you can find the blocks for the special functions in the sf list. in the table below you can also find comparable views of circuit diagrams as well as the information whether or not retentivity can be config- ured for the respective function. in the last column you can locate the position of all sfs by scrolling through the list via the  key. display in the circuit diagram display in logo! designation of the special function re posi- tion in sf on delay (see page 101) 1 off delay (see page 103) 2 on/off delay (see page 105) 14 rk 1 k 1 q trg k 1 retentive on delay (see page 107) 7 r s k1 k1 latching relay (see page 109) re 5 pulse relay (see page 111) re 3 logo! functions
99 logo! manual a5e00119092-01 display in the circuit diagram posi- tion in sf re designation of the special function display in logo! wiping relay (see page 112) 9 edge triggered wiping relay (see page 114) 18 weekly timer switch (see page 115) 4 yearly timer switch (see page 120) 13 up/down counter (see page 122) re 10 operating hours meter (see page 124) 8 symmetric clock genera- tor (see page 128) 6 asynchronous pulse genera- tor (see page 130) 12 logo! functions
logo! manual a5e00119092-01 100 display in the circuit diagram posi- tion in sf re designation of the special function display in logo! random gen- erator (see page 131) 15 fre frequency trigger (see page 133) 11 analog trigger (see page 135) 20 analog comparator (see page 138) 21 stairway light- ing switch (see page 141) 16 comfort switch (see page 143) 17 p message texts (see page 145) 19 en par q softkey (see page 148) re 22 logo! functions
101 logo! manual a5e00119092-01 4.4.1 on delay short description an output with on delay is not switched on until a specified time has expired. symbol in logo! wiring description input trg use input trg (trigger) to start the on delay time parameter t t is the time after which the output is switched (0 to 1 transition of the output sig- nal). output q q is switched on when a specified time t has ex- pired, provided trg is still set. parameter t please not the value specification for parameter t in chap- ter 4.3.2. timing diagram trg t t t a expires q the section of the tim- ing diagram displayed in bold print is found again in the symbol for the on delay. description of the function on 0 to 1 transition of input trg the time t a starts (t a is the current time in logo! . logo! functions
logo! manual a5e00119092-01 102 if the status of input trg is 1 at least for the duration of the configured time t, the output is set to 1 on expiration of this time (the output follows the input with on delay). the time is reset if the status of input trg changes to 0 before the time t has expired. the output is set to 0 when the status at input trg is 0. the time elapsed is reset after a power failure. logo! functions
103 logo! manual a5e00119092-01 4.4.2 off delay short description the output is not reset until a configured time has expired. symbol in logo! wiring description input trg you start the off delay at the negative edge (1 to 0 transi- tion) at input trg (trigger) input r input r resets the on delay time. it also resets the out- put to 0. parameter t t is the time after which the output is switched off (1 to 0 transition of the output sig- nal). output q q is switched on with trg. it holds this state until t has expired. parameter t please not the value specification for parameter t in chap- ter 4.3.2. timing diagram trg t t t a expires q r the bold printed sec- tion of the timing dia- gram is found again in the symbol for the off delay. logo! functions
logo! manual a5e00119092-01 104 description of the function when the status of trg has changed to 1, the output q is switched instantaneously to 1. the actual time t a in logo! restarts on a 1 to 0 transition at trg. the output remains set. when t a reaches the con- figured value t (t a =t), output q is reset to 0 (off delay). the time t a restarts when input trg is switched on and off again. input r (reset) is used to reset the time t a and the output before t a has expired. the time elapsed is reset after a power failure. logo! functions
105 logo! manual a5e00119092-01 4.4.3 on/off delay short description an output with on/off delay is set and reset on expiration of specified times. symbol in logo! wiring description input trg the positive edge (0 to 1 transition) at input trg (trig- ger) starts the time t h for the on delay. the negative edge (1 to 0 transition) at input trg (trig- ger) starts the time t l for the off delay. parameter par t h is the time after which the output is switched on (0 to 1 transition of the output signal). t l is the time after which the output is switched off (1 to 0 transition of the output sig- nal). output q on expiration of the config- ured time t h , output q is switched on provided trg is still set. on expiration of the time t l it is switched off, provided trg was not set again. parameter t h and t l note the value specifications for the parameters t h and t l in chapter 4.3.2. logo! functions
logo! manual a5e00119092-01 106 timing diagram trg t t t h expires q t t l expires t t t the bold printed section of the tim- ing diagram is found again in the symbol for the off delay. description of the function the time t h starts after a 0 to 1 transition at input trg. if the status at input trg is 1 at least for the duration of the time t h , the output is set to 1 on expiration of the time t h (the output follows the input on delayed). the time is reset if input trg changes to 0 before the time t h has expired. time t l starts when the status at input trg returns to 0. if the status at input trg is 0 at least for the duration of t l , the output is set to 0 on expiration of the time t l (the out- put follows the input off delayed). the time is reset if the status at input trg returns to 1 be- fore the time t l has expired. the time elapsed is reset after a power failure. logo! functions
107 logo! manual a5e00119092-01 4.4.4 retentive on delay short description a specified time starts after an input pulse. the output is set on expiration of this time. symbol in logo! wiring description input trg you start the on delay at the negative edge (1 to 0 transi- tion) at input trg (trigger). input r use the input r to reset the on delay time and the out- put. parameter t t is the time after which the output is switched on (out- put transition 0 to 1). output q on expiration of the time t output q is switched on. parameter t note the value specifications in chapter 4.3.2. timing diagram trg t t a expires q r t the bold printed section of the timing diagram is found again in the symbol for the retentive on delay. logo! functions
logo! manual a5e00119092-01 108 description of the function the current time t a starts at the 0 to 1 transition at input trg. output q is set to 1 when t a = t. further switching actions at input trg have no influence on t a . the output and the time t a are only reset to 0 when the status at input r is 1. the time elapsed is reset after a power failure. logo! functions
109 logo! manual a5e00119092-01 4.4.5 latching relay short description input s sets output q. input r resets output q. symbol in logo! wiring description input s use input s to set output q to 1. input r use input r to reset output q to 0 again. if both s and r are 1, the output is reset. parameter par this parameter can be used to switch retentivity on and off. ret: off = no retentivity on = the status is retentive output q q is switched on with a sig- nal at input s. this state is maintained until input r is set. timing diagram s r q switching behavior a latching relay is a simple logic memory. the output value depends on the input states and on the previous output status. the following table shows the logic once again: logo! functions
logo! manual a5e00119092-01 110 s n r n q comment 0 0 x the status is retentive 01 0 reset 10 1 set 11 0 reset (has priority over set) with enabled retentivity the status of the output signal does not change when power is returned after power failure. logo! functions
111 logo! manual a5e00119092-01 4.4.6 pulse relay short description a short oneshot at the input is used to set and reset the output. symbol in logo! wiring description input trg you use input trg (trig- ger)to switch the output q on and off. input r the input r is used to reset the output and the relay. parameter par this parameter can be used to switch retentivity on and off. ret: off = no retentivity on = the status is retentive output q q is switched on with trg and off again with the next trg. timing diagram trg q r the bold printed section of the timing diagram is found again in the symbol for the pulse relay. description of the function output q status is toggled at every 0 to 1 transition of the status at input trg, that is, the output is switched on or off. use input r to reset the pulse relay to initial state, that is, the output is set to 0. after a power failure the pulse relay is reset and the output q is set to 0 if you have not enabled retentivity. logo! functions
logo! manual a5e00119092-01 112 4.4.7 wiping relay pulse output short description an input signal generates a signal of specified length at the output. symbol in logo! wiring description input trg you use input trg (trigger) to start the time for the wip- ing relay. parameter t t is the time after which the output is switched off (1 to 0 transition of the output sig- nal). output q q is switched on with trg as long as the time ta expires and the input is set to 1. parameter t for information on the parameter t refer to the note in chapter 4.3.2. timing diagram trg t has not expired t a expires q the bold printed section of the timing diagram is found again in the symbol for the wiping relay. t description of the function the output status is switched to 1 after the input trg is set to 1. the time t a is started at the same time and the output remains set. logo! functions
113 logo! manual a5e00119092-01 when t a reaches the value specified in t (t a =t), the status of output q is reset to 0 (pulse output). on input trg transition from 1 to 0 before the specified time has expired, the output follows immediately with a 1 to 0 transition. logo! functions
logo! manual a5e00119092-01 114 4.4.8 edgetriggered wiping relay short description an input signal generates an output signal of specified length (retriggering). symbol in logo! wiring description input trg use the input trg (trigger) to start the time for the edgetriggered wiping relay. parameter t t is the time after which the output is switched off (1 to 0 transition of the output sig- nal). output q q is switched on with trg. it holds this state until t has expired. parameter t for information on the parameter t refer to the note in chapter 4.3.2. timing diagram trg t a expires q the bold printed section of the timing diagram is found again in the symbol for the edgetriggered wiping relay. t t description of the function the output status is switched to 1 after the input trg is set to 1. time t a is started at the same time. after t a has reached the value specified in t (t a =t) the output q status is reset to 0 (pulse output). the time t a is reset if input trg changes again from 0 to 1 (retriggering) before the specified time has expired. the output remains switched on. logo! functions
115 logo! manual a5e00119092-01 4.4.9 weekly timer switch short description the output is controlled via a specified on/offdate. the function supports any combination of weekdays. you select the active weekdays by hiding the inactive days. note the logo! 24 version does not have an internal clock. therefore, the weekly timer switch cannot be used for this version. symbol in logo! wiring description the parame- ters cam 1, cam 2 cam 3 in the cam parameter you set the on/offtime respec- tively for one cam of the weekly timer switch. here you configure the days and the timeofday. output q q is switched on when the configured cam is switched on. timing diagram (three examples) monday wednesday tuesday saturday friday thursday sunday q 1 cam 13 1 2 3 111 1 cam1: daily: 06:30 h to 08:00 h cam 2: t uesday: 03:10 h to 04:15 h cam 3: saturday and sunday: 16:30 h to 23:10 h logo! functions
logo! manual a5e00119092-01 116 description of the function every weekly timer switch has three cams. you can config- ure in a time hysteresis for each cam. in the cam setting you specify the on/offtimes. at the ontime, the weekly timer switch switches on the output, if the output is not al- ready switched on. at the offtime, the weekly timer switch switches off the output, if the output is not already switched off. the on and offtimes are in conflict if their specified switching time is the same for the weekly timer switch, but on different cams. in this case cam 3 has priority over cam 2, whereas cam 2 has priority over cam 1. parameter assignment screen form this is what a parameter assignment screen form looks like, for instance, for cam no.1: b01:cam1 d=mtwtfss+ on =06:30 off=08:00 ontime (06.30 h) see display/hide parameter type of protection on page 67 offtime (08.00 h) block b01 cam 1 weekdays (daily) weekday the letters behind the ad=o have the following meaning:  m : monday  t : tuesday  w : wednesday  t : thursday  f : friday  s : saturday  s : sunday logo! functions
117 logo! manual a5e00119092-01 an upper case letter means that the weekday is selected. the character ao means that the weekday is not selected. switching times possible is any time between 00:00 h and 23:59 h. : means there are no on and offtimes. setting the weekly timer switch this is how you specify the switching times: 1. position the cursor on one of the cam parameters of the timer switch (e. g. cam 1). 2. confirm with ok . logo! opens the parameter assign- ment screen form for the cam. the cursor is positioned on the weekday. 3. use and to select one or several weekdays. 4. use to move the cursor to the first position of the on time. 5. set the ontime. modify the value at the respective position, using the keys and . move the cursor around to the various positions, using the keys and . you can only select the value : at the first position (: means: no switching operation). 6. using the key , move the cursor to the first position of the offtime. 7. set the offtime (in same way as in step 5). 8. confirm your entries confirm with ok . the cursor is positioned on the cam 2 parameters. you can now configure another cam. note you can find information on timer switch accuracy in the technical data and in chapter 4.3.2. logo! functions
logo! manual a5e00119092-01 118 weekly timer switch: example the output of the weekly timer switch is to be switched on daily from 05:30 h to 07:40 h. the output should also be switched on every tuesday from 03:10 h to 04:15 h and at the weekends from 16:30 h to 23:10 h. this requires three cams. here are the parameter assignment screen forms of the cams 1, 2 and 3, based on the timing diagram above. cam 1 cam 1 must switch on the output of the weekly timer switch daily from 05:30 h to 07:40 h. b01:cam 1 d=mtwtfss+ on =05:30 off=07:40 cam 2 cam 2 must switch on the output of the weekly timer switch every tuesday from 03:10 h to 04:15 h. b01:cam 2 d=t+ on =03:10 off=04:15 logo! functions
119 logo! manual a5e00119092-01 cam 3 cam 3 must switch on the output of the weekly timer switch every saturday and sunday from 16:30 h to 23:10 h. b01:cam 3 d=ss+ on =16:30 off=23:10 result 1 cam monday wednesday tuesday saturday friday thursday sunday 13 12 3 q 11 1 1 logo! functions
logo! manual a5e00119092-01 120 4.4.10 yearly timer switch short description the output is controlled via a specified on/offdate. note the logo! 24 version does not have a clock. therefore, the yearly timer switch cannot be used for this version. symbol in logo! wiring description input cam in the cam parameters, you configure the on/offtimes for the cams of the yearly timer switch. output q q is switched on when the configured cam is switched on. timing diagram mm.dd+ on=02.20 off=04.03 on off 20th of february at 00:00 h 3rd of april at 00:00 h feb. mar. apr. description of the function at the specified ontime the yearly timer switch switches on the output. at the specified offtime the yearly timer switch switches off the output. the offdate specifies the day on which the output is reset to 0 again. the first value identifies the months, the second value the day. logo! functions
121 logo! manual a5e00119092-01 sample configuration on 1st of march the output of a logo! is to be switched on until the 4th of april. on 7th of july it is switched on once again until the 19th of november. this requires two yearly timer switches for which the respective on times must be configured. the outputs are then linked via an or block. b01:cam mm.dd on =03.01 off=04.04 ontime 1st of march offtime 4th of april b02:cam mm.dd on =07.07 off=11.19 in addition: ontime 7th of july offtime on 19th of november result on off 1st of march at 00:00 h 4th of april at 00:00 h b01 b02 7th of july at 00:00 h 19th of november at 00:00 h logo! functions
logo! manual a5e00119092-01 122 4.4.11 up/down counter short description depending on the configuration, an internal value is counted up or down at every input pulse. the output is set when the configured count value is reached. a special in- put can be used to change the counting direction. symbol in logo! wiring description input r input r resets the internal count value and the output to zero. input cnt the counter counts the 0 to 1 transitions at input cnt. 1 to 0 transitions are not counted. maximum counting frequency at the input termi- nals: 5 hz input dir you specify the counting di- rection via the input dir: dir = 0: upcount dir = 1: downcount parameter par lim: counter value limit at which the output is reset by the internal count value. ret: enabling retentivity output q q is switched on when the count value is reached. logo! functions
123 logo! manual a5e00119092-01 timing diagram r dir par cnt 0 internal count value cnt q description of the function with every positive edge at input cnt the internal counter increments (dir = 0) or decrements (dir = 1) by one count. . output q is set to 1 when the internal value is greater than or equal to the value specified in par. you can use reset input r to reset the output and the inter- nal count value to '000000'. when r=1, the output is 0 and the pulses at input cnt are not counted. configuration of the par parameter b03:par rem = off lim = 000100 + count value retentivity see display/hide parameter type of protection on page 67 the output is set when the internal value is greater than or equal to the value specified in par. the counter stops on over/underflow. lim can lie between 0 and 999999. ret: this parameter is used to switch retentivity on and off for the internal count value cnt. off = no retentivity on = the count value cnt is retentive when retentivity is switched on, the counter value is main- tained in the event of power failure. the count is resumed at the same value after power is returned . logo! functions
logo! manual a5e00119092-01 124 4.4.12 operating hours counter short description a specified time starts when the input is set. the output is set on expiration of this time. symbol in logo! wiring description input r r = 0: counting is enabled if ral is not 1 r = 1: counter has stopped use input r to reset the out- put. the timetogo for the maintenance interval mn is set to the value mn = mi. the time elapsed is main- tained. input en en is the monitoring input. logo! measures the time when this input is set. input ral ral = 0: counting is enabled if ral is not 1 ral = 1: the counter has stopped use input ral (reset all) to reset the counter and the out p ut. that is, out ut . that is ,  output q = 0,  measured operating time ot = 0 and  the timetogo of the maintenance interval mn = mi. logo! functions
125 logo! manual a5e00119092-01 symbol in logo! description wiring parameter par: mi mi: maintenance interval to be specified, in hour units. mi can lie between 0 and 9999 hours. output q the output is set when the timetogo mn = 0 (see the timing diagram). mi = configured count value mn= timetogo ot= total time elapsed since the last 1 signal at the ral input timing diagram mi = configured time interval mn = timetogo ot = total time elapsed since the last 1 signal at the ralinput par: q r ral en mn=mi ot mn=0 the counter holds when r or ral is set mi=5h 1h xr=1h r x logo! functions
logo! manual a5e00119092-01 126 description of the function the hours counter monitors the input en. as long as the status of this input is 1, logo! determines the time ex- pired and the timetogo mn. the logo! displays the times in parameter assignment mode. output q is set to 1 when the timetogo mn = 0. use input r to reset output q and timetogo counter to the specified value mi. the internal counter ot continues the count. use input ral to reset output q and the timetogo counter to the specified value mi. the internal counter ot is reset to 0. viewing mn and ot values  logo! basic with display: in parameter assignment mode you can view the actual values of mn and ot while the program is running.  logo! basic without display: with logo!soft comfort (refer to chapter 7 for additional information) you can read the values as follows. note the pc link must be connected to the logo! before you switch on the power supply. . 1. in the aextras transfero menu, select the menu item ahours countero. a connection is automatically estab- lished to the logo! and the current program is fetched. 2. an info box pops up showing the data. logo! functions
127 logo! manual a5e00119092-01 note the hours counter can be fetched without entering a pass- word. if your logo! without display is equipped with a red mod- ule you cannot fetch the hours counter, because the pro- gram of the logo! will be deleted when you remove the module (to connect the pc cable) . limit value for ot elapsed operating hours are saved in ot when using the input r signal to reset the hours counter. the limit value for the ot counter is 99999 h. when the hours counter reaches this value, no more hours are counted. the ot value ensures retentivity of the hours counter. configuration of the par parameter b03:par mi = 0000h+ monitoring interval in hours parameter protection mi is the specified time interval. it can lie between 0 and 9999. logo! functions
logo! manual a5e00119092-01 128 4.4.13 symmetric clock generator short description the period of the output clock signal is configurable. symbol in logo! wiring description input en use the input en to switch the clock generator on and off. parameter t t is the time during which the output is switched on or off. output q q is toggled periodically de- pending on the clock cycle time t. parameter t note the value specifications in chapter 4.3.2. timing diagram en q t t t t the bold printed section of the timing diagram is found again in the symbol for the symmetric clock generator. description of the function in parameter t you specify the length of the on and off times. via input en (enable) you can switch on the clock generator, that is, the generator toggles the output between 1 and 0, respectively for the duration of the time t, until the input status is 0 again. logo! functions
129 logo! manual a5e00119092-01 note relating to relay outputs: the output contacts of a relay wear slightly when switched under load. you can find information on the number of switching cycles an output of a logo! can safely carry out in the chapter 'technical data' (see chapter a). logo! functions
logo! manual a5e00119092-01 130 4.4.14 asynchronous pulse generator short description the pulse profile of the output can be customized via pulse/pause ratio. symbol in logo! wiring description input en you can use input en to switch the asynchronous pulse generator on and off. input inv you can use input inv to in- vert the output signal of the active asynchronous pulse generator. parameter par you can customize the pe- riod t h and the pulse pause width t l . output q q is toggled periodically, de- pending on the clock cycles t h and t l . timing diagram en inv t h q t l t h t l t h t l t h description of the function in the parameters t h (time high) and t l (time low) you can adjust the period and the pause width. with input inv you can also invert the output. the input block inv only negates the output if it is enabled via en. logo! functions
131 logo! manual a5e00119092-01 4.4.15 random generator short description with a random generator the output is switched on and off again within a specified time. symbol in logo! wiring description input en you can start the on delay time of the random genera- tor at the positive edge (0 to 1 transition) at the enable in- put en. you can start the off delay time of the random genera- tor at the negative edge (1 to 0 transition). parameter par the random on delay time is 0 s to t h . the random on delay time is 0 s to t l . output q on expiration of the on delay time output q is switched on, provided en is still set. on expiration of the off delay time it is switched off, provided en was not set again meanwhile. logo! functions
logo! manual a5e00119092-01 132 parameter t h and t l note the value specifications for the parameters t h and t l in chapter 4.3.2. timing diagram en t is running q t l t h the bold printed sec- tion of the timing dia- gram is found again in the symbol for the off delay. description of the function a random time (on delay) between 0 s and t h is deter- mined and started at the 0 to 1 transition of the status at input en. the output is set to 1 on expiration of the on delay time, if the status at input en is 1 at least for the duration of the on delay time. the time is reset if the status at input en returns to 0 be- fore the on delay time has expired. when the status at input en returns to 0, a random time (off delay) between 0s and t l is determined and started. the output is reset to 0 on expiration of the off delay time, if the status at input en is 0 at least for the duration of the off delay time. the time is reset if the status at input en returns to 1 be- fore the on delay time has expired. the time elapsed is reset after a power failure. logo! functions
133 logo! manual a5e00119092-01 4.4.16 frequency threshold trigger short description the output is switched on and off, depending on two speci- fied frequencies. symbol in logo! wiring description fre input fre at input fre you connect the input that supplies the pulses to be counted. use  inputs i5/i6 for fast counting operations (only logo! 12/24 rc/ rco and logo! 24): max. 1 khz.  any other input or circuit component for counting low frequencies. parameter par: sw  , sw  g_t sw  : on threshold sw  : off threshold g_t: time interval or gate time during which the pulses are measured. output q q is switched on and off de- pending on sw  and sw  . timing diagram q sw  = 5 fa = 9 fa = 10 fa = 8 fa = 5 g_t fre sw  = 9 logo! functions
logo! manual a5e00119092-01 134 description of the function the threshold switch measures the signals at input fre. the pulses are captured across a specified period g_t. output q is switched on if the value measured within the time g_t is higher then the on and off threshold. q is switched off again when the measured pulse rate is equal to/lower than the off threshold value. configuration of the par parameter b03:par sw  =0050+ sw  =0048 g_t:01:00s on threshold parameter protection time interval for pulses off threshold sw  is the on threshold. the permitted range is 0000 to 9999. sw  is the off threshold. the permitted range is 0000 to 9999. g_t is the time interval during which the pulses at the fre input are measured. the permitted range for g_t is 00.05 s to 99.95 s. note when you specify a time g_t of 1 s, the logo! returns the current frequency in parameter f a in hz. f a is always the sum of the measured pulses per time unit g_t. logo! functions
135 logo! manual a5e00119092-01 4.4.17 analog threshold switch short description the output is switched on when the analog value exceeds a specified on threshold. the output is switched on when the analog value drops below a specified off threshold (hys- teresis). symbol in logo! wiring description input ax at input ax you apply the analog signal you want to evaluate. always use the terminals i7 (ai1) or i8 (ai2), only the logo! 12/24 rc/rco and logo! 24 or those of an analog module. 010 v is equivalent to 01000 (internal value). parameter par:  ,  , sw  , sw     : gain in % range of values 0..1000 %  : offset range of values  999 sw  : on threshold range of values  19990 sw  : off threshold range of values  19990 output q q is set and reset depend- ing on the thresholds. gain and offset parameters note the information relating to the gain and offset parame- ters in chapter 4.3.6. logo! functions
logo! manual a5e00119092-01 136 timing diagram q 1000 0 ax sw  sw  description of the function this function fetches the analog value of a signal at the analog input (ai1 ,ai2...ai8). the offset parameter is then added to the analog value. the result is multiplied by the gain parameter. since this is given as a %age, the value 1000% for instance is equivalent to a multiplication by 10. see chap- ter 4.3.6. output q is set to 1 if this value exceeds the on threshold ( sw  ). q is reset to 0 again after the value reaches or drops below the off threshold ( sw  ). logo! functions
137 logo! manual a5e00119092-01 configuration of the par parameter the gain and offset parameters are used to adapt the used sensors to the respective application. parameter assignment: b03:par sw  =+00000 sw  =+00000  =0050+ gain in % parameter protection on threshold  off threshold press the key offset sw  =+00000 sw  =+00000  =0050+  =+200  display in parameter assignment mode (example): b02:par sw  =+400 sw  =+200 ax =+20 logo! functions
logo! manual a5e00119092-01 138 4.4.18 analog comparator short description the output is switched on if the difference ax ay exceeds the set threshold. symbol in logo! wiring description inputs ax and ay at the inputs ax and ay, ap- ply the analog signals for which you want to evaluate the difference. use the terminals i7 (ai1) and i8 (ai2), only the logo! 12/24 rc/rco and logo! 24 or those of an analog module. parameter par:  ,  ,     : gain in % range of values 0..1000 %  : offset range of values  999  : threshold output q q is set to 1 if the difference axay exceeds the thresh- old. gain and offset parameters note the information relating to the gain and offset parame- ters in chapter 4.3.6. logo! functions
139 logo! manual a5e00119092-01 timing diagram q for ax - ay > 200 ax 1000 0 ay 1000 0 axay 1000 0 >200 200 description of the function the analog comparator function carries out the following calculations: 1. the value configured in the offset parameter is added to ax and ay. 2. ax and ay are multiplied by the gain parameter. since this is given as a %age, the value 1000% for instance is equivalent to a multiplication by 10. 3. the function forms the difference of the analog values axay output q to 1 if this differential value exceeds the threshold you have configured under  . otherwise q is reset to 0. calculation rules q = 1, if: [(ax + offset)  gain] [(ay + offset)  gain] > threshold configuration of the par parameter the gain and offset parameters are used to adapt the used sensors to the respective application. b03:par  =00000+  =0050  =+200 gain in % parameter protection threshold offset  logo! functions
logo! manual a5e00119092-01 140 example for the controls of a heater, the supply and return line tem- peratures t v (e.g. with a sensor at ai1) and t r (e.g. with a sensor at ai2) are to be compared. a switching operation is to be triggered (e.g. burner on) if the return line temperature deviates by more than 15 c from the supply line temperature. the physical temperature is to be displayed in parameter assignment mode. available are thermal elements with the following technical data: 30 to +70 c, 0 to 10 v dc. application internal mapping 30 to +70 c = 0 to 10v dc 0 to 1000 0 c 300  offset = 300 range of values: 30 to +70 c = 100 1000  gain = 100/1000 = 0,1 = 10 % switching threshold = 15 c threshold = 15 see also chapter 4.3.6. parameter assignment:  b03:par  =00015  =0010+  =-300 display in parameter assignment mode (example): b03:par  =20 ax = 10 ay = 30 b03:par  =30 ax=10 ay = 20 logo! functions
141 logo! manual a5e00119092-01 4.4.19 stairway lighting short description the input pulse (edge control) starts a specified time. the output is reset on expiration of this time. 15 s prior to the expiration of this time an off prewarning is generated. symbol in logo! wiring description input trg use the input trg (trigger) to start the timer for the stairway lighting switch (off delay). parameter t t is the time after which the output is switched off (1 to 0 transition of the output sta- tus). default timebase is the min- ute. output q on expiration of the time t q is switched off. 15 s prior to the expiration of this time the output is switched to 0 fro the duration of 1 s. parameter t note the value specifications in chapter 4.3.2. timing diagram 15s t a expires t 1s q trg prewarning time prewarning duration logo! functions
logo! manual a5e00119092-01 142 description of the function the output q is set to 1 on a 0 to 1 transition at input trg. at the 1 to 0 transition of the status at input trg the current time ta starts. the output q remains set. 15 s before t a reaches the time t the output q is reset to 0 for a time of 1 s. when t a = t, the output q is reset to 0. when input trg is switched on and off again while t a ex- pires, t a is reset (retriggering option). the time elapsed is reset after a power failure. how to change the timebase you can also set other values for the prewarning time and prewarning period . timebase t prewarning time prewarning duration seconds* 750 ms 50 ms minutes 15 s 1s hours 15 min 1 min *only feasible for programs with a cycle time < 25 ms see also adetermining the cycle timeo in appendix b. logo! functions
143 logo! manual a5e00119092-01 4.4.20 multifunctional switch short description switch with two different functions:  pulse switch with off delay  switch (continuous lighting) symbol in logo! wiring description input trg use input trg (trigger) to switch on the output q (off delay or continuous light- ing). the active output q can be reset with trg. parameter par t h is the time after which the output is switched off (1 to 0 transition of the output status). t l is the period during which the input must be set in order to enable the con- tinuous lighting function. output q the output q is switched on with trg. depending on the pulse width at the input trg, it is switched off again on expiration of a specified time, or reset by setting trg once again. parameter t h and t l note the value specifications in chapter 4.3.2. (as a re- minder: aalways specify a time t  0.10 s. the time t is not defined for t = 0.05 s and t= 0.00 so) logo! functions
logo! manual a5e00119092-01 144 timing diagram t a expires t h q trg t l description of the function the current time t a starts and the output q is set to 1 at the 0 to 1 transition of the status at input trg. when t a reaches the time t h , the output q is reset to 0. the time elapsed is reset after a power failure. at the 0 to 1 transition of the status at input trg and if the status '1' is set at least for the duration of the time t l , the continuous lighting function is enabled and output q is switched on continuously. if the input is switched once again, trg resets t h neverthe- less and the output q is switched off. logo! functions
145 logo! manual a5e00119092-01 4.4.21 message texts short description displaying a specified message text in run mode. symbol in logo! wiring description input en the 0 to 1 transition of the status at input en (enable) starts the output of the mes- sage text. parameter p p represents the priority of the message text. ack: acknowledgment of the message text. parameter par par is the text for the mes- sage output. output q q is set as long as the mes- sage text is displayed. restriction a maximum of five message text functions are possible. description of the function on 0 to 1 transition of the status at input en the display shows in run mode your specified message text . acknowledgment disabled (ack = off): on 1 to 0 transition of the status at input en the message text is hidden. acknowledgment enabled (ack = on): on a 1 to 0 transition of the status at input en, the mes- sage text is held until acknowledged with ok . when en is 1, you cannot acknowledge the message text. when multiple message text functions are triggered with en=1, the message text with the highest priority is shown (0=lowest, 9=highest). you can toggle between the standard display and the mes- sage text display using the keys and . logo! functions
logo! manual a5e00119092-01 146 example this is how a message text might be displayed: en=1 motor 2 3000 hours mainte- nance! 06.21.01 th 09:30 parameter assignment screen form this is how to configure the priority and the acknowledg- ment: b03:p priority 0 ack=off parameter assignment screen form for p priority status of the acknowledgment 1. increase priority to 1: cursor on '0' + 2. change to 'ack': press the key 3. enable 'ack': per or logo! displays: b03:p priority 1 ack=on parameter assignment screen form for p priority 1 status of acknowledgment 'on' 4. confirm messages with ok this is how to configure the message text: .. .. .. .. parameter assignment screen form for par logo! functions
147 logo! manual a5e00119092-01 using the key , select the row for the message text. confirm with ok to open the editing mode for this line. use the keys and to select the letter to be displayed. move the cursor from one position to the other, using the keys and . the list of available characters is the same as for the pro- gram name. you can find a character set in chapter 3.6.4. confirm the changes with ok . exit the editing mode with esc . in order to output a parameter (e.g.: the display of a mea- surement or function value) as message text in a line, se- lect this line with the key and then press the key : par .. .. .. confirm with ok to open editing mode: b01>t use the keys and to select the blocks to be displayed and their corresponding parameters . use the keys and to select the block or the parameter you want to view. select the parameter with ok . exit parameter assignment mode with esc . your changes are applied. logo! functions
logo! manual a5e00119092-01 148 4.4.22 softkey short description this logical function has the effect of a mechanical momen- tary switch or of a switch. symbol in logo! wiring description en par q input en on a 0 to 1 transition of the status at input en (enable) the output q is switched on, provided 'switch=on' was confirmed in parameter as- signment mode. parameter par when programming : par gives you the option to use the function as momen- tary pushbutton in one cycle or to use it as switch. ret: off = no retentivity on = the status can be saved retentive in run mode : switch: switches the push- button or switch on or off. output q switches on if en=1 and if switch=on was confirmed with ok . factory default the factory default setting of 'par' is 'pushbutton'. timing diagram switch en q logo! functions
149 logo! manual a5e00119092-01 description of the function the output is switched on after input en is set and, in pa- rameter assignment mode, if oono is selected in the param- eter 'switch' 'on' and confirmed with ok . whether the function was configured as pushbutton or switch is here of no concern. the output is reset to '0' at three events:  at the 0 to 1 transition of the status at input en.  when the function was configured as pushbutton and one cycle has expired since it was switched on.  when the position 'off' was selected in the parameter 'switch' and confirmed with ok in parameter assign- ment mode. configuration of the par parameter in programming mode: 1. select the 'softkey' function. 2. select input en and confirm with ok. the cursor is now positioned below 'par'. 3. change to the input mode of 'par': confirm with ok (the cursor is now positioned to 'on') b03:par on= rem=off the function is configured as 'pushbutton' the status is not retentive this is how to change 'par' to 'switch' and activate reten- tivity (ret=on): 4. toggling between the 'pushbutton' and 'switch' function: per or logo! functions
logo! manual a5e00119092-01 150 b03:par on/off rem=off function as 'switch' the status is not retentive 5. change to retentivity: per or 6. enable retentivity: per or b03:par on/off rem=on function as 'switch' the status is retentive 7. confirm your entries with with ok in parameter assignment mode (run mode): here, you can switch the parameter 'switch' on and off (on/off). in run mode logo! displays: b03:par switch=off let us assume you want to activate 'switch' (on). 1. change into editing mode: confirm with ok (the cursor is now positioned to 'off') 2. change from 'off' to 'on': per or 3. confirm your entries with with ok b03:par switch=on here, for example, the switch is on logo! functions
151 logo! manual a5e00119092-01 5 configuring logo! we consider 'parameter assignment' as the configuration of block parameters. you can set delay times for time func- tions, switching times for the timer switches, the threshold value of a counter, the monitoring interval of an operating hours counter and the on and off thresholds of the triggers. you can configure the parameters:  in programming mode  in parameter assignment mode in parameter assignment mode, the programmer config- ures the parameters. we introduced this parameter assignment mode to allow editing of the parameters without having to change the pro- gram. in this way, for example, a user can edit parameters without having to switch to programming mode. the advan- tage: the program (and thus the circuit) is protected but can still be modified by the user of the circuit to suit re- quirements. note in parameter assignment mode, the logo! continues processing of the program.
logo! manual a5e00119092-01 152 5.1 switching to parameter assignment mode in run mode, you can switch to parameter assignment mode by pressing the esc key: 06.21.01 mo 09:30 esc ...and press logo! switches to parameter assignment mode and dis- plays parameter assignment menu: >stop set param set clock prg name description of the four menu options in the parameter assign- ment menu  stop you are going to use this menu item to stop your program and, as a result, open the main menu in programming mode. proceed as follows: 1. move the '>' character to 'stop': per or 2. confirm the 'stop': ok stop prg >no yes 3. move the '>' character to 'yes': per or 4. confirm 'yes': ok confi g urin g logo!
153 logo! manual a5e00119092-01 logo! returns to the main menu: >program.. pc/card.. clock.. start  set param the diverse parameters are described in the following chapters 5.1.1 to 5.1.3.  set clock the menu item 'set clock' is only executed in a logo! equipped with a clock (logo!..c). in 'set clock' you can set the internal clock of the logo!. closer detail in sec- tion 5.2.  prg name under this menu item you can only read your program name. in parameter assignment mode it is not possible to change the program name. 5.1.1 parameter parameters are:  the delay times of a timer relay.  the switching times (cams) of a timer switch.  the threshold value of a counter  the monitoring time for an operating hours counter  the switching thresholds of a threshold switch. each one of the parameters is identified by its block num- ber and mnemonics. examples: b01:t block number mnemonic  t: ...is a configurable time.  cam 1: ...is the first cam of a timer switch.  par: ...denotes multiple counter parameters that can be monitored. confi g urin g logo!
logo! manual a5e00119092-01 154 5.1.2 selecting the parameters select a parameter: 1. in the parameter assignment menu via 'set param' op- tion or stop >set param set clock prg name 2. press ok logo! displays the first parameter. if parameters can- not be set, you can use esc to return to the parameter assignment menu. b01:t t a = 00:00m t = 12:00m parameter value set for the parameter the current time in the logo! press esc no param parameters cannot be changed: esc returns you to the parameter assignment menu 3. now, select the desired parameter: use the or logo! displays one parameter respectively in separate windows. 4. if you want to edit a parameter, select it and press ok . confi g urin g logo!
155 logo! manual a5e00119092-01 5.1.3 changing the parameters to change a parameter, you first have to select it (see ose- lecting a parameter). you change the value of the parameter in the same way as you entered it in programming mode: 1. move the cursor to the point at which you want to make the change: per or 2. change the value: per or 3. confirm the value: ok b01:t t a = 00:00m move:  or  change the value:  or  done: ok t = 0 1:00m note in parameter assignment mode, you cannot change the unit of the delay time or the parameter protection for the parameter t. this is only possible in programming mode. current value of a time t if you view a time t in parameter assignment mode, it look like this: b01:t t a = 00:00m t = 12:00m set time t current time t a you can change the set time t (see ochanging a parame- ter). confi g urin g logo!
logo! manual a5e00119092-01 156 current value of the timer switch if you view a cam of a timer switch in parameter assign- ment mode, it looks like this, for example: the timer switch is off (sta- tus '0' at the output) the timer switch is on (status '1' at the output) b02:cam 1 off=10:00 day = su the circuit state of the timer switch is displayed: on =09:00 1 1 0 logo! displays the circuit state of the timer switch rather than the circuit state of a cam. the circuit state of the timer switch depends on all three cams (cam 1, cam 2 and cam 3). current value of a counter if you view the parameter of a counter in parameter assign- ment mode, it looks like this: cnt=000028 lim=000300 b03:par switching threshold current count value current value of an operating hours counter if you view the parameter of an operating hours counter in parameter assignment mode, it looks like this: b05:par mi = 0100h mn = 0017h ot =00083h timetogo operating hours elapsed monitoring time confi g urin g logo!
157 logo! manual a5e00119092-01 current value of a threshold switch if you view the parameter of a threshold switch in parame- ter assignment mode, it looks like this: b06:par off threshold measured value on threshold sw  =0050 sw  =0048 fa  =0012 confi g urin g logo!
logo! manual a5e00119092-01 158 5.2 setting the timeofday and the date (logo! ... c) you can set the tod and the date  in parameter assignment mode  in programming mode. how to set the tod and the date in parameter assignment mode: 1. open the parameter assignment mode (refer to chap- ter 5.1) 2. select ' set clock ' ( or ) and press ok . set clock _th 15:30 mm.dd.yy 06.21.01 the cursor position precedes the day of the week. 3. select the day of the week: per or 4. move the cursor to the next position: per or 5. change the value: per or 6. set the correct tod. repeat steps 4 and 5. 7. set the correct date. repeat steps 4 and 5 8. close your entries: ok how to set the tod and the date in programming mode: 1. switch to programming mode: in run, execute the menu item 'stop'. (see page 45) 2. select 'clock..' ( or ) and press ok . 3. select 'set clock' ( or ) and press ok now you can set the day of the week and the time, as de- scribed above (as of step 3.). confi g urin g logo!
159 logo! manual a5e00119092-01 6 logo! program modules in logo! you can only keep one program stored in memory. if you want to modify the program or write another program without deleting the first one, you must archive it somewhere. you can use program modules/cards to do this. you can copy the program stored in the logo! to a pro- gram module/card. you can then insert the program mod- ule/card in another logo! and copy the program to this logo! . you can use the program module/card to do the following:  archive programs  duplicate programs  mail programs  write and test programs out of the field at your office and then transfer it to a logo! in the switching cabinet. logo! is supplied with a hood. you receive the program module/card separately. note you do not require a module for storing your logo! pro- gram permanently. the logo! program is already stored permanently when programming mode is closed. below we shall introduce the two modules that you can purchase for your logo! . both of them can accommodate the entire program memory of a logo! . module order no. yellow module: for copying 6ed1 0561ba000aa0 red module: with knowhow/ copy protection 6ed1 0564ba000aa0
logo! manual a5e00119092-01 160 6.1 overview of the modules yellow program module programs can be transferred from the yellow module to the device and vice versa. red program module a program is protected if it is transferred from a red mod- ule to the logo! . such a protected program can only run if the red module remains inserted in logo! during runtime. a protected program cannot be edited. a program is not protected anymore when the correct password is entered. if you create a program for the red module and want to edit it at a later time you must assign it a password. compatibility ... under current versions (0ba3 devices): a module written in one of the basic versions (0ba3 de- vices) can be read in all other basic versions. ... under previous versions (0ba0 to 0ba2 devices): a module  written in a standard version can be read in all the other versions.  written in a logo! ...l version, can be read in all other logo! ...l versions; but not in a standard version.  written in a logo! ...lb11 version, can be read in all other logo! ...lb11 versions; but not in a standard ver- sion or in a logo! ...l version. ... 0ba3 devices > 0ba0 to 0ba2 devices: a module written in one of the basic versions (0ba3 de- vices) can only be read in 0ba3 devices. logo! pro g ram modules
161 logo! manual a5e00119092-01 upward compatibility the new 0ba3 devices support upward compatibility. a module written in one of the standard, long or bus versions (0ba0 to 0ba2 devices) can be read in all basic versions (0ba3 devices). note re upward compatibility: an adaptation of the program or an upgrade of the logo! basic is required (and sensible) in some cases in order to achieve appropriate results. see the information on a fast inputs o in chapter 2.3.2. 6.2 removing and inserting modules when removing a red module (knowhow/copy protection), note that: the program stored on this module can only run if the module remains inserted during runtime. if the module is removed the logo! reports a 'no pro- gram' error. removal of the red module during runtime leads to impermissible operate states. always heed the following warning: ! warning do not put your finger or objects made of metal or any other conductive material in the open slot of the program module/card. the socket for the program module/card may be live if l1 and n have been incorrectly wired. the program module/card must always be re- placed by a skilled technician. logo! pro g ram modules
logo! manual a5e00119092-01 162 removing the module this how to remove the program module/card: carefully insert a screwdriver into the slot at the upper end of the program module/card and ease it out of the slot a little. you can now remove the program module/card: inserting the program module/card the slot for the program module/card is chamfered at the lower right edge. the program module/card also has a chamfered edge. this prevents you from inserting the pro- gram module/card the wrong way around. insert the pro- gram module/card into the slot until it engages. logo! pro g ram modules
163 logo! manual a5e00119092-01 6.3 copying from the logo! to the module this is how you copy a program to the program module/ card: 1. insert the program module/card into the slot. 2. switch the logo! to programming mode. in run mode: press esc and execute the menu item 'stop'. (see page 45) >program.. pc/card.. clock.. start logo! main menu 3. move the '>' to opc/cardo: press the key 4. press ok . the transfer menu opens. >pc   card card  = logo! 5. move the '>' to ' logo  card ': press the key 6. press ok . logo! copies the program to the program module/card. when logo! has finished copying, it automatically returns to the main menu: >program.. pc/card.. clock.. start logo! pro g ram modules
logo! manual a5e00119092-01 164 the program is now also stored on the program module/ card. you can now remove the program module/card: do not forget to replace the cover . if power is lost while logo! is copying the program you must copy it once again when power is returned. note if the program in the logo! is protected with a password x, the copied program in the module/card is also protected with the same password. logo! pro g ram modules
165 logo! manual a5e00119092-01 6.4 copying from the module to logo! you have a program module/card containing your program. you can copy the program to logo! in two ways :  automatic copying when logo! starts up (power on) or  via the pc/card menu in logo!. note f the program in the module/card is protected with the password x, the copied program in the logo! is also protected with the same password. before you copy a module written in another device type, refer once again to the information on 'compatibility of logo! versions or devices' in chapter 6.1. automatic copying when logo! starts up proceed as follows: 1. switch off the power supply to the logo! (power off) 2. remove the slot cover. 3. insert the program module/card into the appropriate slot. 4. switch off the power supply to the logo! . result: logo! copies the program from the program mod- ule/card to logo!. when logo! has finished copying, it displays the main menu: >program.. pc/card.. clock.. start logo! pro g ram modules
logo! manual a5e00119092-01 166 note before you switch the logo! to run, you must ensure that the system you are controlling with logo! does not represent a source of hazard. 1. move the '>' character to start: per or 2. press ok. using the pc/card menu to copy read the note about changing the program module/card. this is how you copy a program from the program module/ card to logo!: 1. insert the program module/card 2. switch the logo! to programming mode. in run mode: press esc execute the menu item 'stop'. (see page 45) >program.. pc/card.. clock.. start 3. move the '>' to opc/cardo: press the key 4. press ok . the transfer menu opens. 5. move the '>' to ' card  logo ': or pc   card >card  = logo! 6. press ok . logo! copies the program from the program module/card to logo!. when logo! has finished copying, it automati- cally returns to the main menu. logo! pro g ram modules
167 logo! manual a5e00119092-01 7 logo! software the program logo!soft comfort is available as a pro- gramming package for the pc. this software includes the following features:  offline program generation for your application  simulation of your circuit (or program) on the computer  generation and printing of a block diagram  saving the program to the hard disk or other storage media  program transfer from the logo! to the pc from the pc to logo!  reading the operating hours counter  setting the tod  summertime/wintertime conversion the logo! alternative thus, logo!soft comfort offers you an alternative to con- ventional means of planning: 1. first you develop your applications at your desktop. 2. you simulate the application in your computer and test whether or not it functions properly before the circuit is actually put to use. 3. you print out the entire circuit in one or several block diagrams, sorted according to outputs. 4. you archive your circuits in your pc file system. in this way you can retrieve a circuit directly for future changes. 5. you transfer the program to logo! at a touch with just a few key operations. your logo! is quickly retooled.
logo! manual a5e00119092-01 168 logo!soft comfort in logo!soft comfort you can create your circuit pro- grams efficiently and in a comfortable, well arranged way (owiring per keyboarda). programs are created on the pc desktop per the drag&drop routine. once you have created you program, you can have the system evaluate your pro- gram in order to determine the required logo! version, or you can determine this before you start programming. one particularly userfriendly feature is the offline program simulation facility, which enables the simultaneous status display of multiple special functions and permits extensive documentation of the programs created. this optional pro- gramming software also offers a comprehensive online help on cd rom. logo!soft comfort runs under windows 95/98, windows nt 4.0, windows me  , windows 2000  , linux  , and mac os x  . it is capable of server operation and offers all the freedom and comfort for programming you could expect. logo!soft comfort v3.0 this is the current version of logo!soft comfort. as of version 3.0 you will find all the functions and functionality included in the new devices, exactly in the way they are described in this manual. upgrade from logo!soft comfort v1.0 and v2.0 if you own an old version of logo!soft comfort you can transfer the old program to the new devices, however, you cannot use the new functions in such programs. in such cases you must upgrade to the current version. you can only install the upgrade on a full version of logo!soft comfort logo!soft comfort v1.0 or v2.0. upgrades & infos at our internet url http://www.ad.siemens.de/logo/html_00/softcomfort.htm, you can download the software upgrades and demo ver- sions free of costs. logo! software
169 logo! manual a5e00119092-01 7.1 connecting the logo! to a pc connecting a pc cable to connect the logo! to a pc you require the logo!-topc link. (order no. 6ed1 0571aa000ba0 ). remove the cover or the program module/card of your logo! and connect the cable. connect the other end of the cable to the serial port of your pc. logo! to pc pc
logo mode there are two ways of communication between the pc and the logo!. logo! to transfer mode in run state or auto- matically when the logo! power supply is switched on, provided the link is plugged in. this is how you switch the logo! to the mode pc  logo: 1. switch the logo! to programming mode: in run mode, press esc and execute the menu item 'stop'. (see page 152) 2. select 'pc/card': per or 3. confirm with ok 4. select 'pc
logo': per or 5. confirm with ok logo! is now in pc
logo and displays: pc
stop: press esc = logo! logo! software
logo! manual a5e00119092-01 170 this is how the logo! is switched automatically to mode pc  logo: 1. switch off the power supply to logo! 2. remove the cover or the program module/card and connect the cable. 3. switch on power. logo! switches automatically to pc
logo mode. the pc can now communicate with the logo! see how this is done directly in the online help of logo!soft com- fort. use the esc key on the logo! if you want to interrupt the pc communication. note if the program you have created in logo!soft comfort is password protected, the 'pc  logo' function transfers the program and the password to the logo! . the pass- word prompt is switched on when the device exits the transfer mode. the upload of a password protected program created in logo! is only possible after the correct password is en- tered in logo!soft comfort. logo! software
171 logo! manual a5e00119092-01 8 applications we have provided a small collection of applications in this manual to give you an impression of the versatile use of logo!. . for these examples we have recorded once again the original solution of the circuit diagram and compared it with the logo! solutions. you can find solutions for the following tasks: page staircase or corridor lighting system 172 . . . . . . . . . . . . . . . automatic door 176 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ventilation system 183 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . industrial gate 188 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . central controlling and monitoring of several industrial gates 192 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . luminous rows 196 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . rainwater pump 200 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . other applications 204 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . note the logo! applications are freely available to all our cus- tomers. the examples they contain are not binding and are included to provide general information on the fields of application for logo!. customerspecific solutions may be different. the user undertakes to ensure proper operation of the system. we refer to the standards and systemrelated installation regulations of the respective country. errors are excepted and the right to make changes re- served. these applications as well as tips for other applications are also found at our internet url: http://www.ad.siemens.de/logo
logo! manual a5e00119092-01 172 8.1 staircase or corridor lighting 8.1.1 demands on a staircase lighting system the basic requirements for a staircase lighting system are as follows:  when someone is using the staircase, the lighting should be switched on.  if noone is in the staircase the lights should be switched off in order to save energy. 8.1.2 previous solution the two conventional options for switching the lights:  the pulse relay  the automatic staircase time switch the wiring for these two lighting systems is identical. ??? ??? ??? ??? ??? ??? ??? ??? lights switches distribution per pulse relay or automatic staircase lighting switch distribution box components used  switches  automatic staircase time switch or pulse relay applications
173 logo! manual a5e00119092-01 lighting system with pulse relay function of a lighting system with pulse relay:  actuate any pushbutton: the lighting is switched on  actuate any of the pushbuttons once again: the lighting is switched off. disadvantage: one often forgets to switch off the lights. lighting system with an automatic staircase time switch when an automatic staircase time switch is used, the light- ing system behaves as follows:  actuate any pushbutton: the lighting is switched on  on expiration of the preset time the lights switch off au- tomatically. disadvantage: the light cannot be switched on for a lon- ger period of time (e.g. when cleaning the staircase). the switch for continuous lighting is usually installed on the au- tomatic staircase time switch that may be difficult or impos- sible to access. 8.1.3 lighting system with logo! with the logo! you can replace the automatic staircase time switch or the pulse relay. you can also implement both functions (timed off delay and pulse relay) in a single unit. what is more, you can incorporate extra functions without making any alterations to the wiring. here are some exam- ples:  pulse relay with logo!  automatic staircase time switch with logo!  multifunctional switch with logo! switch light on switch on continuous lighting switch light off applications
logo! manual a5e00119092-01 174 wiring of the lighting system with logo! 230 rc ?? ?? ?? ?? lights switches l1n i1 i3i6i7i8 q1 q2 q3 q4 l n pe ii4 i5 i1 i2 i3 i1 i2 ii3 the external wiring of a lighting system with a logo! is no different than it is for a conventional staircase and corridor lighting system. only the automatic staircase time switch/ pulse relay is replaced. supplementary functions are en- tered directly in logo!. pulse relay with logo! i1 switch: q1 lights x output q1 is toggled with a gate pulse at input i1. automatic staircase time switch with logo! i1 switch: q1 lights t 06:00m output q1 is switched on for the duration of 6 minutes with a gate pulse at input i1. applications
175 logo! manual a5e00119092-01 multifunctional switch with logo! i1 switch: q1 lights t h / t l output q1 is switched on for a specified time t h with a gate pulse at input i1. the continuous lighting function is enabled by holding down the pushbutton for a specified time t l . 8.1.4 special features and expansion options other options for increasing comfort or saving energy are, for example:  a flashing function that indicates that the light is about to be switched off automatically.  you can integrate various central functions: central off central on (panic button) control of all lamps or individual circuits via a day- light control switch control via integrated timer switch (e.g. continuous lighting only until 24.00 h; disabling at specific times) automatic off for the continuous lighting on expiration of a preset time (e.g. after 3 hours) applications
logo! manual a5e00119092-01 176 8.2 automatic door you often find automatic door control systems at the en- trance to supermarkets, public buildings, banks, hospitals etc. 8.2.1 demands on an automatic door  when somebody approaches the door, it must open au- tomatically.  the door must remain open until the doorway is cleared.  when the doorway is cleared, the door must close auto- matically after a short time. ????? ???? ???? ???? ???? ???? ???? ???? ???? out- side inside b1 b2 limit switch closed limit switch open main switch q1 s1 s2 motion detector main switch motion detector motion detector the door is usually motordriven and equipped with a slip coupling. this prevents people from being squeezed in and injured. the control system is connected to the mains via a master switch. applications
177 logo! manual a5e00119092-01 8.2.2 previous solution k1 k2 k2 k1 k3 k3 open close s2 s1 k3 b1 b2 k3 k4 k4 b2 k3 b1 s2 open door waiting time auxiliary circuit l1 n when someone enters the detection range of the motion sensors b1 or b2, the door is opened via k3. after the detection range of the two motion sensors has been cleared for a minimum period, k4 enables the closing motion. 8.2.3 door control system with logo! with logo! you can simplify this circuit considerably. what is left to do is to connect the motion sensors, limit switches and power contactors to the logo! . applications
logo! manual a5e00119092-01 178 wiring the door control system with logo! 230 rc l1n i4 i5i6i7i8 q1 q2 q3 q4 k1 k2 open close b1 b2 s2 s1 l1 n i1 i2 i3 1 2 1 2 1 2 1 2 components used  k1 main contactor open  k2 main contactor close  s1 (n.c. contact) limit switch closed  s2 (n.c. contact) limit switch open  b1 (n.o. contact) infrared motion detector outdoor  b2 (n.o. contact) infrared motion detector indoor applications
179 logo! manual a5e00119092-01 door control system with logo! , block diagram & 1 1 1 & i4 i3 q2 q1 rs i1 i2 1 i4 t= 4s close open x & x q1 q2 this is what the circuit diagram of the conventional solution looks like. you can simplify this circuit if you make use of the logo! functions. you can use the off delay to replace the latching relay and the on delay. the block diagram below illustrates this simplification: & 1 1 1 & i4 i3 i1 i2 x q2 q1 x 10 s close open limit switch door closed limit switch door open motion de- tector q1 q2 applications
logo! manual a5e00119092-01 180 8.2.4 special features and expansion options options for increasing comfort and user friendliness are, for example:  you can connect an additional control switch with the positions: open automatic closed (o-a-c)  you can connect a buzzer to an output of the logo! to warn of the closing of the door.  you can implement time and direction dependent enable functions for opening of the door (e.g. opening only dur- ing business hours; after business hours to be opened only from inside). 8.2.5 enhanced solutions with logo! 230 rc wiring the logo! expansion l1n i4 i5i6i7i8 k1 k2 open close b1 b2 s2 s1 l1 n buzzer s3 o-a-c h1 q1 q2 q3 q4 i1 i2 i3 1 2 1 2 1 2 1 2 applications
181 logo! manual a5e00119092-01 block diagram of the enhanced logo! solution x x x x cam1: day= mo..fr on = 09:00 off =18:00 cam 2: day= sa on = 08:00 off =13:00 cam1: day= mo..fr on = 09:00 off =19:00 cam 2: day= sa on = 08:00 off =14:00 i1 i2 motion detector b1 motion detector b2 t= 10 s x i5 control switch door open q2 close output i4 limit switch door open q1 open q2 close x q1 i1 i2 open output motion detector b1 motion detector b2 i3 limit switch door closed i6 control switch close door detecting motion motor for opening motor for closing applications
logo! manual a5e00119092-01 182 detecting motion during business hours, the motion detector b1 initiates the opening of the door as soon as somebody wants to enter the shop from outside. motion detector b2 initiates the opening of the door if somebody wants to leave the shop. after closing time, the motion detector b2 continues to be used to open the door for 1 hour to allow the customers to leave the shop. motor for opening output q1 is switched on to open the door when the follow- ing occurs:  the control switch at 15 is operated (the door is to be constantly open) or  the motion detectors indicate that somebody is ap- proaching the door and  the door is not yet fully open (limit switch at i4). motor for closing output q2 is switched on to close the door when the follow- ing occurs:  the control switch at 16 is operated (the door is to be constantly closed) or  the motion detectors indicate that there is nobody near the door and  the door is not yet fully closed (limit switch at i3). buzzer connect the buzzer to output q3. the buzzer sounds for a short time (in this case 1 second) when the door is closed. enter the following circuit at q3 in the block diagram: t= 1 s x q3 buzzer q2 close out- put applications
183 logo! manual a5e00119092-01 8.3 airconditioning system 8.3.1 demands on an airconditioning system the airconditioning system is used for the controlled sup- ply of fresh air to a room and to exhaust the contaminated air in the room. let us examine following example: freshair fan flow sensor exhaust fan flow sensor  the room is equipped with an exhaust fan and a fresh air fan.  both fans are monitored by a flow sensor.  the pressure in the room must not be allowed to rise above the atmospheric pressure.  the freshair fan must only be switched on if reliable functioning of the exhaust fan is signaled by the flow sensor.  a warning lamp indicates if one of the fans fails. applications
logo! manual a5e00119092-01 184 the circuit diagram for conventional solutions is as follows: k1 k5 k5 s1 exhaust air fresh air s0 k3 k2 operation auxiliary circuit l1 n s2 k1 v > s2 h1 k4 s3 v > k5 error h2 k2 k4 the fans are monitored by flow sensors. if, after a short delay, no air flow is measured the system is switched off and an error is reported. acknowledge this by pressing the off pushbutton. fan monitoring requires an evaluation circuit with several switching devices in addition to the flow sensors. the eval- uation circuit can be replaced by a single logo! unit. wiring the airconditioning system with logo! 230 rc l1 n i1 i3 i6 i7 i8 q1 q2 q3 q4 k1 k2 exhaust fan freshair fan s1 l1 n s2 s3 v> v> h1 h2 s0 i4 i5 i1 i2 i3 i1 i2 i3 1 2 1 2 1 2 1 2 applications
185 logo! manual a5e00119092-01 components used  k1 main contactor  k2 main contactor  s0 (n.c. contact) stop pushbutton  s1 (n.o. contact) start pushbutton  s2 (n.o. contact) flow sensor  s3 (n.o. contact) flow sensor  h1 indicator lamp  h2 indicator lamp circuit diagram of the logo! solution this is what the circuit diagram of the airconditioning sys- tem looks like with a logo! : x i1 on q3 error i2 off q1 exhaust fan q2 freshair fan q1 exhaust fan i3 exhaust air flow sensor x i2 off error x t= 10 s x t= 10 s x x x i3 exhaust air flow sensor i4 freshair flow sensor exhaust fan q1 exhaust fan q2 q3 applications
logo! manual a5e00119092-01 186 8.3.2 advantages of using logo! when using the logo!, you require less switchgear. that saves you installation time and space in the control cabinet. you might even be able to use a smaller control cabinet. additional options when using logo!  the free output (q4) can be used as a potentialfree contact for signaling a fault or a power failure.  it is possible to switch off of the fans via sequential cir- cuit. these functions can be incorporated without additional switchgear. block diagram of the enhanced logo! solution the fans at q1 and q2 are switched on and off as shown in the following circuit: x t= 10 s t= 30 s q1 exhaust fan q2 freshair fan on i2 off fault q3 x x i3 exhaust air flow sensor i2 off error t= 10 s t= 10 s x x x i3 exhaust air flow sensor i4 freshair flow sensor q1 exhaust fan q2 exhaust fan q3 i1 applications
187 logo! manual a5e00119092-01 you can also generate a message at output q4: q3 error q4 message the relay contacts of output q4 are always closed when the system is in operation. relay q4 does not drop unless there is a power failure or a fault in the system. this con- tact can be used for remote messaging, for example. applications
logo! manual a5e00119092-01 188 8.4 industrial gate ?? ?? ?? ?? ?? ?? ?? ?? ?? ?? ?? ?? ?? ?? ?? ?? warning light safety pressure bar the entrance to a company's premises is often closed with a gate. the gate is only opened to let vehicles in and out. the gate is controlled by the gateman. 8.4.1 demands on the gate control system  the gate is opened and closed by operating a pushbut- ton in the gatehouse. the gateman can monitor the op- eration of the gate at the same time.  the gate is normally fully opened or closed. however, the gate motion can be interrupted at any time.  a flashing light is activated 5 seconds before the gate begins to move and continues for as long as the gate is in motion.  a safety pressure bar prevents harm to persons and objects from getting trapped or damaged when the gate closes. applications
189 logo! manual a5e00119092-01 8.4.2 previous solution diverse kinds of control systems are used to operate auto- matic gates. the gate control circuit diagram shows one option. k1 k5 k3 s1 open close s0 k3 k2 flashing light auxiliary circuit l1 n k1 h1 k4 s5 p > k6 k6 k1 s2 s2 k3 k2 k4 open close k5 s5 p > s1 k3 k1 s4 s3 wiring the gate controls with logo! 230 rc l1 n i4 i5 i6 i7 i8 q1 q2 q3 q4 k1 k3 open close s4 s3 l1 n s1 s2 s0 s5 p > s5 p > flashing light h1 open close stop i1 i2 i3 1 2 1 2 1 2 1 2 applications
logo! manual a5e00119092-01 190 components used  k1 main contactor  k2 main contactor  s0 (n.c. contact) stop pushbutton  s1 (n.o. contact) open switch  s2 (n.o. contact) close pushbutton  s3 (n.c. contact) open position switch  s4 (n.c. contact) closed position switch  s5 (n.c. contact) safety pressure bar block diagram of the logo! solution t= 5 s t= 5 s x x x x q1 open q3 flas- hing light q2 close i3 i4 i3 i6 i5 i1 i2 q2 q1 safety bar gate is closed gate is open stop push- button start push- button open stop pushbutton close push- button t= 2 s i2 i1 open push- button close push- button start push- button close the open or close start switches initiate the gate's mo- tion in the appropriate direction provided it is not already moving in the other direction. the gate's motion is halted via the stop pushbutton or the relevant limit switch. clos- ing of the gate is also interrupted by the safety bar. applications
191 logo! manual a5e00119092-01 8.4.3 wiring the logo! solution in our enhanced solution the gate will automatically open again when the safety bar is operated. x x i6 safety bar x q2 i3 i4 gate is open stop push- button x i1 q2 open pushbutton t= 5 s q1 open t= 5 s x q2 close i3 i6 i5 i2 q1 safety bar gate is closed stop pushbutton close push- button q3 flashing light t= 2 s applications
logo! manual a5e00119092-01 192 8.5 centralized control and monitoring of several industrial gates ? ? ? ? ? ? ? ? ? ? ? ? 1 safety pressure bar 2 flashing warning light master ? ? ? ? ? ? ? ? 1 2 1 2 1 2 fm asi + fm asi + fm asi + often, a company's premises can be entered at several locations. not all of the gates can always be monitored lo- cally by personnel. they must therefore be able to be moni- tored and operated by the gateman who sits in a central gatehouse. it must also be possible for a member of staff to open and close the gate locally. for every gate we implement one logo! 230 rc and one as interface function module. the bus interconnects the modules and the master. in this chapter, we will describe a gate control system. the structure of the other gate control systems is identical. applications
193 logo! manual a5e00119092-01 8.5.1 demands on the gate control system  every gate is opened and closed by means of a cord operated switch. the gate is here fully opened or closed.  every gate can also be opened and closed per local pushbutton.  the gate can be opened and closed via the bus link to the gatehouse. the gate open or gate closed status is indicated.  a flashing light is activated 5 seconds before the gate begins to move and continues for as long as the gate is in motion.  a safety pressure bar prevents harm to persons and objects from getting trapped or damaged when the gate closes. wiring the gate controls with logo! 230 rc and fm asi n l1 n i3 i4 i5 i6 i7 i8 k1 k2 l1 gate gate flashin g s0 s1 s2 s3 s4 s5 s6 p > s6 p > i2 i1 q1 q2 q3 q4 as interface + fm asi 1 2 1 2 1 2 1 2 applications
logo! manual a5e00119092-01 194 components used  k1 main contactor for opening  k2 main contactor for closing  s0 (n.o. contact) cordoperated switch open  s1 (n.o. contact) cordoperated switch close  s2 (n.o. contact) open switch  s3 (n.o. contact) close pushbutton  s4 (n.c. contact) open gate position switch  s5 (n.c. contact) close gate position switch  s6 (n.c. contact) safety pressure bar higherlevel control system  q5 open gate position switch  q6 close gate position switch  i9 external open gate pushbutton  i10 external close gate pushbutton applications
195 logo! manual a5e00119092-01 block diagram of the logo! solution  1 closed safety bar gate is closed gate is closed t 05.00s  1 q1 i1 i2 i3 i5 i9 x i6 i4 q2 x i10 gate open &  1 & =1 & & & &  1  1 i5 x i5 x x i7 x i6 i7 x i6 i7 x q3 q5 x q6 i5 i6 t 05.00s t 02.00s gate closed flas- hing light gate is open gate open gate open gate is open gate is open open gate by hand close gate by hand safety bar safety bar closed gate is closed gate is closed gate is open closed open the open gate and close gate start pushbuttons move the gate in the appropriate direction provided it is not already moving in the other direction. the gate motion ends at the respective limit switch. closing of the gate is also interrupted by the safety bar. applications
logo! manual a5e00119092-01 196 8.6 luminous rows luminous rows 2 luminous rows 1 luminous rows 4 luminous rows 3 corridor office when planning lighting systems for commercial locations, the type and number of lamps used is determined by the illuminance required. for reasons of cost efficiency, fluores- cent tubes arranged in luminous rows are often used. they are divided into separate switching circuits, according to the way the room is used. 8.6.1 demands on the lighting system  these separate luminous rows are switched on and off locally.  if there is sufficient daylight, the rows on the window side of the room are automatically switched off via day- light control switch.  the lights are switched off automatically at 20.00.  it must be possible at all times to switch the lights on and off locally. applications
197 logo! manual a5e00119092-01 8.6.2 previous solution b1 l1 n e1 e1 lx> k6 e5 k5 e4 k4 e3 k3 e2 k3 k4 k5 k6 s1 s2 s3 s4 k1 k2 k2 k2 k1 the lamps are switched on and off with a pulse relay that is controlled per pushbuttons at the door. regardless of this, they are reset by the time switch or by the daylight control switch via the central off input. the length of the off com- mands must be reduced per wiping relays in order to make it possible to switch the lights on and off locally after they have been switched off. components required:  switches s1 to s4  daylight control switch b1  timer switch e1  wiping relays k1 and k2  pulse switches with central off k3 to k6 disadvantages of the previous solution  a substantial amount of switchgear is required in order to implement these functions.  due to the high proportion of mechanical components, high wear and tear and maintenance expenditure is to be expected.  changing the function demands considerable efforts. applications
logo! manual a5e00119092-01 198 8.6.3 luminous row control with logo! 230 rc l1 n i1 i3 i6 i7 i8 q1 q2 q3 q4 l1 n e2 e3 e4 b1 lx< luminous row 1 e5 luminous row 2 luminous row 3 luminous row 4 s1 s2 s3 s4 i1 i3 i1 i3 i4 i5 i1 i2 i3 i1 i2 i3 i1 i2 i3 i1 i2 i3 1 2 1 2 1 2 1 2 components used  s1 to s4 (n.o. contact) switches  b1 (n.o. contact) daylight control switch applications
199 logo! manual a5e00119092-01 block diagram of the logo! solution x t= 1s q2 mo..su 20:00 20.01 mo..su 21:00 21.01 off pulse generated via timer switch i5 t= 1s daylight con- trol switch x i5 off pulse generated via daylight control switch i1 i2 i3 i4 x x q1 q4 q3 luminous row 3 corridor side luminous row 4 corridor side luminous row 1 window side luminous row 2 window side advantages of the logo! solution  you can connect the lamps directly to the logo!, pro- vided the power consumption of the individual outputs does not exceed its switching capacity. if higher loads must be switched you should use a power contactor.  connect the daylight control switch directly to an input of the logo! .  you do not need an external timer switch, because this function is integrated in the logo! .  due to the reduced amount of switchgear, you can install a smaller and spacesaving subsidiary distribu- tion cabinet.  fewer devices are required  the lighting system can be easily modified.  additional switching times can be set as required (se- quential circuit for the off pulses at the end of the day).  the function of the daylight control switch can easily be applied to all lamps or modified group of lamps. applications
logo! manual a5e00119092-01 200 8.7 service water pump the use of rainwater as an addition to the drinking water supply is gaining importance in the domestic housing area. this saves money and helps protect the environment. for example, rainwater can be used for:  washing clothes  irrigation system for gardens  watering indoor plants  car wash  toilet flushing installations the sketch below illustrates how such a rainwater utiliza- tion system is operated: ??? ??? ??? ?? ?? ??? ??? ??? ??? ??? ??? dryrun protection on drinking water supply on dryrun protection off drinking water supply off pump pressure tank pressure switch s1 ??? ??? s2 s3 s4 m1 rainwater reservoir service water connection control in the distribution box drinking water supply line k4 rainwater supply line the rainwater is collected in a reservoir. from the reservoir a pumping station supplies a respective line system. from there it can be tapped in the same way as normal drinking water. if the reservoir should run dry it can be topped up with drinking water. applications
201 logo! manual a5e00119092-01 8.7.1 demands on the control system of a service water pump  the system must be capable of supplying service water at all times. in case of emergency, the control system must automatically switch over to drinking water supply.  when switching over to the drinking water supply an ingress of rainwater into the mains system must be pre- vented.  the service water pump must not be switched on if rain- water is low in the reservoir (dryrun protection). 8.7.2 previous solution k1 k2 k3 pump tracking time s1 k3 s4 k3 dryrun protection auxiliary circuit l1 n k4 s3 k4 pure water supply line p< k2 s3 s2 y1 the pump and a solenoid valve are controlled by means of a pressure switch and 3 float switches installed in the rain- water reservoir. the pump must be switched on when the pressure level in the cylinder drops below minimum. once the operating pressure has been reached, the pump is switched off again after a tracking time of a few seconds. the tracking time prevents an oscillation of the water pump if water is drawn off over any length of time. applications
logo! manual a5e00119092-01 202 8.7.3 service water pump with logo! 230 rc l1 n i4 i5 i6 i7 i8 q1 q2 q3 q4 k1 y1 pump s4 s3 l1 n s1 s2 p< drinking water supply line i1 i2 i3 1 2 1 2 1 2 1 2 apart from the logo!, all you need is a pressure switch and the float switches to control the pump. if you are using a 3phase ac motor, you must use a power contactor for switching the pump. for singlephase ac pump systems you must provide a contactor if the current consumption of the ac motor exceeds the capacity of the output relay q1. the power of a solenoid valve is low enough to allow direct controlling.  k1 main contactor  y1 solenoid valve  s1 (n.o. contact) pressure switch  s2 (n.o. contact) float switch  s3 (n.c. contact) float switch  s4 (n.c. contact) float switch applications
203 logo! manual a5e00119092-01 circuit diagram of the logo! solution i2 float switch for drin- king water supply off drinking water supply line q2 float switch for drinking water supply off i1 pressure switch i3 float switch for dry run protection on i4 float switch for dry run protection off x t = 20 s x pump q1 i3 8.7.4 special features and expansion options the circuit diagram shows how you can wire the pump con- trols and the solenoid valve. the layout corresponds to that of the circuit diagram. you also have the option to integrate further functions for specific applications that could other- wise only be realized in conventional technology under additional expenditure of switchgear, e.g.:  enabling the pump at specific times  indication of imminent or existing shortage of water  reporting of system faults applications
logo! manual a5e00119092-01 204 8.8 further application options apart from the shown samples, we have also published a collection of applications on the web (www.ad.siemens.de/ logo/html_00/application.htm). there you can find amongst other things:  irrigation system for greenhouse plants  controlling of conveyor systems  controlling of a bending machine  shop window lighting  bell system (e.g. in a school)  parking lot surveillance  outdoor lighting  control system for shutters  domestic outdoor and indoor lighting  control system for a cream stirrer  sports hall lighting  constant load on 3 consumers  sequential control system for cablewelding machines for large crosssections  step switch (e.g. for fans)  sequential control for a boiler  control system for several pump sets with centralized operation  cutting device (e.g. for detonating fuses)  monitoring periods of utilization, e.g. of a solar energy system  intelligent foot switches, e.g. for speed preselection)  controlling an elevating platform  impregnation of textiles; controlling the heating and con- veyor belts  silofilling system and lots more. applications
205 logo! manual a5e00119092-01 on the web you can also find descriptions and the corre- sponding circuit diagrams of the applications. you can read these *.pdf files with the adobe acrobatreader. and if you have installed the logo!soft or logo!soft comfort pro- gramming software on your pc, you can simply download the relevant circuit diagrams at the touch of a button, adapt them to your requirements, transfer them into logo! via the pc cable and start to use them . advantages of using logo! the use of logo! is highly beneficial, especially in areas  in which you can use the logo! to replace multiple auxiliary switchgear with the integrated functions,  where you want to economize wiring and installation efforts because logo! keeps the wiring oin its heado.  where you want to reduce component space in the con- trol cabinet/distribution you might even be able to re- duce the size of your control cabinet/distribution box.  in which you can add or change functions subsequently, without having to install an additional switchgear or change the wiring.  where you want to offer your customers additional func- tions for domestic and commercial housing installation. examples: domestic security systems: with logo! to switch a lamp on regularly or open and close your shutters while you are on holiday. central heating: with logo! run the circulation pump only when you actually require water or heat- ing. refrigerating systems: with logo! defrost your re- frigerating systems at regular intervals; this is more lenient on energy costs. you can illuminate aquaria and terraria on a timede- pendent basis. applications
logo! manual a5e00119092-01 206 last not least you can:  use commonly available switches and pushbuttons, which makes it easy to install a domestic system.  logo! directly to your house installation; the integrated power supply makes it possible. do you want more info? you can find more info relating to the topic logo! on our internet site: http://www.ad.siemens.de/logo. do you have any suggestions? there are definitely many more useful applications for the logo! . if you know of one, why not write to us? we will collect all the suggestions made and distribute as many of them as we can. it does not matter how unusual or simple your logo! might be. just write to us. we shall be de- lighted to receive all your suggestions. write to: siemens ag a&d as mvm logo! pobox 48 48 d90327 nuremberg applications
207 logo! manual a5e00119092-01 a technical data a.1 general technical data criterion complies with values logo!basic: dimensions (wxhxd) 72 x 90 x 55 mm weight approx. 190 g installation on a 35 mm profile rail 4 module widths or wall mounting logo! expansion module: dimensions (wxhxd) 36 x 90 x 55 mm weight approx. 90 g installation on a 35 mm profile rail 4 module widths or wall mounting climatic environmental conditions ambient temperature horizontal installation cold: iec 60068-2-1 0 ... 55 c horizontal installation vertical installation heat: iec 60068-2-2 0 ... 55 c 0 ... 55 c storage/transport 40 c ... +70 c relative humidity iec 60068-2-30 from 10 to 85 % no condensation air pressure 795 ... 1080 hpa pollutants iec 60068-2-42 iec 60068-2-43 so 2 10 cm 3 /m 3 , 4 days h 2 s 1 cm 3 /m 3 , 4 days mechanical environmental conditions type of protection ip20 vibrations: iec 60068-2-6 5 ... 9 hz (constant am- plitude 3.5 mm) 9 ... 150 hz (constant ac- celeration 1 g)
logo! manual a5e00119092-01 208 criterion values complies with shock iec 60068-2-27 18 shocks (halfsine wave 15g/11 ms) drop iec 60068-2-31 drop height 50 mm free fall (packaged) iec 60068-2-32 1 m electromagnetic compatibility (emc) interference emission en 55011 limit class b group 1 limit class for asi opera- tion electrostatic discharge iec 61000-4-2 severity 3 8 kv air discharge 6 kv contact discharge electromagnetic fields iec 61000-4-3 field strength 10 v/m hf conductance on cables and cable shields according iec 61000-4-6 10 v burst pulses iec 61000-4-4 severity 3 2 kv (supply and signal lines) energy carriers single pulse (surge) (applies only to logo! 230 ... iec 61000-4-5 severity 2 0.5 kv (power lines) symmetrical 1 kv (power lines) asym- metrical information on iec / vde safety measurement of clearance and creepage distance iec 60664, iec 61131-2, en 50178 ul 508, csa c22.2 no.142 with logo! 230 r/rc also vde 0631 fulfilled insulation strength iec 61131-2 fulfilled technical data
209 logo! manual a5e00119092-01 a.2 technical data: logo! 230... and logo! dm8 230r logo! 230 rc logo! 230 rco logo! dm8 230r power supply input voltage 115/240 v ac/dc 115/240 v ac/dc permissible range 85 ... 253 v ac 85 ... 253 v dc 85 ... 253 v ac 85 ... 253 v dc permissible mains frequency 47 ... 63 hz 47 ... 63 hz power consumption  115 v ac 10 ... 30 ma 10 ... 30 ma  240 v ac 10 ... 20 ma 10 ... 20 ma  115 vdc 5 ... 15 ma 5 ... 15 ma  240 v dc 5 ... 10 ma 5 ... 10 ma voltage failure buffering  115 v ac/dc ty p 10 ms ty p 10 ms  11 5 v ac/dc typ. 10 ms typ. 10 ms  240 v ac/dc y ty p 20 ms y ty p 20 ms  240 v ac/dc t yp. 20 ms t yp. 20 ms power loss at  115 v ac 1.1 ... 3.5 w 1.1 ... 3.5 w  240 v ac 2.4 ... 4.8 w 2.4 ... 4.8 w  115v dc 0.5 ... 1.8 w 0.5 ... 1.8 w  240 v dc 1.2 ... 2.4 w 1.2 ... 2.4 w buffering the clock at 25 c typ. 80h accuracy of the realtime clock max.  5 s / tag digital inputs number 8 4 electrical isolation no no technical data
logo! manual a5e00119092-01 210 logo! dm8 230r logo! 230 rc logo! 230 rco input voltage l1  signal 0  signal 1  signal 0  signal 1 < 40 v ac > 79 v ac < 30 v ac > 79 v ac < 40 v ac > 79 v ac < 30 v ac > 79 v ac input current at  signal 0  signal 1 < 0.03 ma >008ma < 0.03 ma >008ma  si gna l 1 > 0 . 08 m a > 0 . 08 m a delay time at  0 to 1 typ. 50 ms typ. 50 ms  1 to 0 y typ. 50 ms y typ. 50 ms line length (unshielded) 100 m 100 m digital outputs number 4 4 output type relay outputs relay outputs electrical isolation yes yes in groups of 1 1 activation of digital input yes yes continuous current i th max. 10 a per relay max. 10 a per relay and max. 20 a across all 4 relays incandescent lamp load (25,000 switching cycles) at 230/240 v 115/120 v 1000 w 500 w 1000 w 500 w fluorescent tubes with choke (25,000 switching cycles) 10 x 58 w (at 230/240 v ac) 10 x 58 w (at 230/240 v ac) technical data
211 logo! manual a5e00119092-01 logo! dm8 230r logo! 230 rc logo! 230 rco fluorescent tubes, conven- tionally compensated (25,000 switching cycles) 1 x 58 w (at 230/240 v ac) 1 x 58 w (at 230/240 v ac) fluorescent tubes, uncom- pensated (25,000 switching cycles) 10 x 58 w (at 230/240 v ac) 10 x 58 w (at 230/240 v ac) short circuitproof cos 1 power protection b16 600a power protection b16 600a shortcircuit proof cos 0.5 to 0.7 power protection b16 900a power protection b16 900a derating none; across the to- tal temperature range none; across the to- tal temperature range parallel switching of outputs to increase power not permitted not permitted protection of output relay (if desired) max. 16 a, characteristic b16 max. 16 a, characteristic b16 switching rate mechanical 10 hz 10 hz ohmic load/lamp load 2 hz 2 hz inductive load 0.5 hz 0.5 hz technical data
logo! manual a5e00119092-01 212 a.3 technical data: logo! 24... and logo! dm8 24 logo! logo! 24 dm8 24 logo! 24 rc (ac) logo! 24 rco (ac) power supply input voltage 24 v dc 24 v ac permissible range 20.4 ... 28.8 v dc 20.4 ... 26.4 v ac reverse polarity protection yes permissible mains frequency 47 ... 63 hz power consumption from 24 v dc logo! 24 10 ... 25 ma logo! dm8 24 30 ... 45 ma 0.3 a per output 120 ... 20 ma voltage failure buffering typ. 5 ms power loss at 24 v logo!24 0,2 ... 0,6 w logo! dm8 24 0.8 ... 1.1 w 0.5 ... 2.9 w (ac) buffering the clock at 25 c typ. 80h accuracy of the realtime clock max.  5 s / tag digital inputs number logo! 24 :8 logo! dm8 24 :4 8 electrical isolation no no input voltage l+ l  signal 0 < 5 v dc < 5 v ac g  signal 1 > 8 v dc > 12 v ac technical data
213 logo! manual a5e00119092-01 logo! 24 rc (ac) logo! 24 rco (ac) logo! logo! 24 dm8 24 input current at  signal 0 < 1.0 ma (i1...i6) < 0.05 ma (i7, i8) < 1.0 ma  signal 1 (, ) > 1.5 ma (i1... i6) > 0.1 ma (i7, i8) > 2.5 ma delay time at  0 to 1 typ. 1.5 ms (i1...i4) <1.0 ms (i5, i6) typ. 300 ms (i7,i8) typ. 1.5 ms  1 to 0 y() typ. 1.5 ms (i1...i4) <1.0 ms (i5, i6) typ. 300 ms (i7,i8) typ. 15 ms line length (unshielded) 100 m 100 m analog inputs number only logo! 24 : 2 (i7 and i8) range 0 ... 10 v dc max. input voltage 28,8 v dc digital outputs number 4 4 output type transistor, currentsourcing relay outputs electrical isolation no yes in groups of 1 activation of digital input yes yes output voltage  supply voltage output current max. 0.3 a continuous current i th max. 10 a technical data
logo! manual a5e00119092-01 214 logo! 24 rc (ac) logo! 24 rco (ac) logo! logo! 24 dm8 24 incandescent lamp load (25,000 switching cycles) at 1000 w fluorescent tubes with choke (25,000 switching cycles) 10 x 58 w fluorescent tubes, conven- tionally compensated (25,000 switching cycles) 1 x 58 w fluorescent tubes, uncom- pensated (25,000 switching cycles) 10 x 58 w short circuitproof and over- loadproof yes shortcircuit current limitation approx. 1 a derating none; across the to- tal temperature range none; across the to- tal temperature range short circuitproof cos 1 power protection b16 600a shortcircuit proof cos 0.5 to 0.7 power protection b16 900a parallel switching of outputs to increase power not permitted not permitted protection of output relay (if desired) max. 16 a, characteristic b16 switching rate mechanical 10 hz electrical 10 hz ohmic load/lamp load 10 hz 2 hz inductive load 0.5 hz 0.5 hz technical data
215 logo! manual a5e00119092-01 a.4 technical data: logo! 12/24... and logo! dm8 12/24r logo! logo! 12/24 rc logo! logo! dm8 12/24r power supply input voltage 12/24 v dc 12/24 v dc permissible range 10.8 ... 15.6 v dc 20.4 ... 28.8 v dc 10.8 ... 15.6 v dc 20.4 ... 28.8 v dc reverse polarity protection yes yes power consumption  12 v dc  24 v dc 10 ... 100 ma 10 ... 75 ma 30 ... 100 ma 30 ... 75 ma voltage failure buffering  12 v dc  24 v dc typ. 2 ms typ. 5 ms typ. 2 ms typ. 5 ms power loss  12 v dc  24 v dc 0.1 ... 1.2 w 0.2 ... 1.8 w 0.4 ... 1.2 w 0.8 ... 1.8 w buffering of the clock at 25 c typ. 80h accuracy of the realtime clock max.  5 s / day electrical isolation no no digital inputs number 8 4 electrical isolation no no input voltage l+  signal 0 < 5 v dc < 5 v dc g  signal 1 > 8 v dc > 8 v dc technical data
logo! manual a5e00119092-01 216 logo! dm8 12/24r logo! logo! 12/24 rc logo! input current at  signal 0 si l 1 < 1.0 ma (i1...i6) < 0.05 ma (i7, i8) 1 5 a (i1 i6) < 1.0 ma  signal 1 > 1.5 ma (i1... i6) > 0.1 ma (i7, i8) > 1.5 ma delay time at  0 to 1 typ. 1.5 ms <1.0 ms (i5, i6) typ. 300 ms (i7,i8) typ. 1.5 ms  1 to 0 y() typ. 1.5 ms <1.0 ms (i5, i6) typ. 300 ms (i7,i8) typ. 1.5 ms line length (unshielded) 100 m 100 m analog inputs number 2 (i7, i8) range 0 ... 10 v dc max. input voltage 28,8 v dc digital outputs number 4 4 output type relay outputs relay outputs electrical isolation yes yes in groups of 1 1 activation of digital input yes yes output voltage output current continuous current i th (per terminal) max. 10 a per relay max. 10 a per relay and max. 20 a across all 4 relays technical data
217 logo! manual a5e00119092-01 logo! dm8 12/24r logo! logo! 12/24 rc logo! incandescent lamp load (25,000 switching cycles) at 1000 w 1000 w fluorescent tubes with choke (25,000 switching cycles) 10 x 58 w 10 x 58 w fluorescent tubes, conven- tionally compensated (25,000 switching cycles) 1 x 58 w 1 x 58 w fluorescent tubes, uncom- pensated (25,000 switching cycles) 10 x 58 w 10 x 58 w short circuitproof and over- loadproof shortcircuit current limitation derating none; across the to- tal temperature range none; across the to- tal temperature range short circuitproof cos 1 power protection b16 600a power protection b16 600a shortcircuit proof cos 0.5 to 0.7 power protection b16 900a power protection b16 900a parallel switching of outputs to increase power not permitted not permitted protection of output relay (if desired) max. 16 a, characteristic b16 max. 16 a, characteristic b16 switching rate mechanical 10 hz 10 hz electrical ohmic load/lamp load 2 hz 2 hz inductive load 0.5 hz 0.5 hz technical data
logo! manual a5e00119092-01 218 a.5 technical data: logo! am 2 logo! am 2 power supply input voltage 12/24 v dc permissible range 10.8 ... 15.6 v dc 20.4 ... 28.8 v dc power consumption 25 ... 50 ma voltage failure buffering typ. 5 ms power loss at  12 v  24 v 0.3 ... 0.6 w 0.6 ... 1.2 w electrical isolation no reverse polarity protection yes ground terminal for connecting ground and shielding of the analog measuring line. analog inputs number 2 type unipolar input range 010 v or 020 ma resolution 10 bit, standardized to 01000 cycle time for analog value generation 50 ms electrical isolation no line length (shielded and twisted) 10m encoder supply voltage none error limit +/ 1.5 % interference frequency suppres- sion 55 hz technical data
219 logo! manual a5e00119092-01 switching capacity and service life of the relay outputs ohmic load switching cycles/million switched current/a 0.1 0.2 0.3 0.4 0.5 246810 maximum 10 a maximum 10 a maximum 10 a 12/24 v ac/dc 115/120 v ac 230/240 v ac figure a switching capacity and service life of the contacts at ohmic load (heating) inductive load switching cycles/million switched current/a 0.1 0.2 0.3 0.4 0.5 3 2 1 0.6 0.7 0.8 0.9 1.0 maximum 2 a maximum 3 a maximum 3 a 12/24 v ac/dc 115/120 v ac 230/240 v ac figure b switching capacity and service life of the contacts at highly induc- tive load to iec 947-5-1 dc 13/ac 15 (contactors, solenoid coils, motors) technical data
logo! manual a5e00119092-01 220 a.6 technical data: logo!power 12 v logo! power 12 v is a switchedmode primary power supply unit for logo! devices. two current intensities are available. logo! power 12 v / 1.9 a logo! power 12 v / 4.5 a input data input voltage 120 ... 230 v ac permissible range 85 ... 264 v ac permissible mains frequency 47 ... 63 hz voltage failure buffering > 40 ms (at 187 v ac) input current 0.3 ... 0.18 a 0.73 ... 0.43 a make current (25 c)  15 a  30 a device protection internal recommended circuit breaker (iec 898) in mains in- feed > 6 a characteristic d > 10 a characteristic c output data output voltage overall tolerance adjustment range residual ripple 12 v dc +/- 3 % 11.1 ... 12.9 v dc < 200 mv pp output current overcurrent limiting 1.9 a 2.4 a 4.5 a 4.5 a efficiency  80 % parallel switching to increase power yes electromagnetic compatibility interference suppression en 500811, en 55022 class b interference immunity en 50082-2 technical data
221 logo! manual a5e00119092-01 logo! power 12 v / 4.5 a logo! power 12 v / 1.9 a safety electrical isolation, primary/ secondary yes, selv (to en 60950/vde 0805) safety class ii (to iec 536/vde 0106 t1) type of protection ip 20 (to en 60529/vde 470 t1) ce marking ul/csa certification fm approval yes yes; ul 508 / csa 22.2 in preparation general details ambient temperature range 20 ... +55 c, natural convection storage and transport tem- perature - 40 ... +70 c connections on input respectively on terminal (1 x. 2.5 mm2 o. 2 x 1.5 mm 2 ), each for l1 and n connections on output two terminals (1x.2.5 mm 2 o. 2x 1.5 mm 2 ), each for l+ and m installation on 35 mm din rail, snapon dimensions in mm (wxhxd) 72 x 80 x 55 126 x 90 x 55 approx. weight 0.2 kg 0.4 kg technical data
logo! manual a5e00119092-01 222 a.7 technical data: logo!power 24 v logo! power 24 v is a switchedmode primary power supply unit for logo! devices. two current intensities are available. logo! power 24 v / 1,3 a logo! power 24 v / 2.5 a input data input voltage 120 ... 230 v ac permissible range 85 ... 264 v ac permissible mains frequency 47 ... 63 hz voltage failure buffering 40 ms (at 187 v ac) input current 0.48 ... 0.3 a 0.85 ... 0.5 a make current (25 c) < 15 a < 30 a device protection internal recommended circuit breaker (iec 898) in mains in- feed > 6 a characteristic d > 10 a characteristic c output data output voltage overall tolerance adjustment range residual ripple 24 v dc +/- 3 % 22.2 ... 25.8 v dc < 250 mv pp output current overcurrent limiting 1.3 a 1.6 a 2.5 a 2.8 a efficiency > 80 % parallel switching to increase power yes electromagnetic compatibility interference suppression en 500811, en 55022 class b interference immunity en 50082-2 technical data
223 logo! manual a5e00119092-01 logo! power 24 v / 2.5 a logo! power 24 v / 1,3 a safety electrical isolation, primary/ secondary yes, selv (to en 60950/vde 0805) safety class ii (to iec 536/vde 0106 t1) type of protection ip 20 (to en 60529/vde 470 t1) ce marking ul/csa certification fm approval yes yes; ul 508 / csa 22.2 yes; class i, div. 2, t4 general details ambient temperature range 20 ... +55 c, natural convection storage and transport tem- perature - 40 ... +70 c connections on input respectively one terminal (1 x. 2.5 mm2 o. 2 x 1.5 mm 2 ), each for l1 and n connections on output two terminals (1x.2.5 mm 2 o. 2x 1.5 mm 2 ), each for l+ and m installation on 35 mm din rail, snapon dimensions in mm (wxhxd) 72 x 80 x 55 126 x 90 x 55 approx. weight 0.2 kg 0.4 kg technical data
logo! manual a5e00119092-01 224 a.8 technical data: logo! contact 24/230 logo! contact 24 and logo! contact 230 are switching modules for direct switching of ohmic loads up to 20 a and motors up to 4 kw (without noise emission, humfree). logo! contact 24 logo! contact 230 operating voltage 24 v dc 230 v ac; 50/60 hz switching capacity utilization category ac-1: switching of ohmic loads at 55 c operating current at 400 v output of threephase loads at 400 v 20 a 13 kw utilization category ac-2, ac-3: motor with slip ring induction/cage armature operating current at 400 v output of threephase loads at 400 v 8.4 a 4 kw shortcircuit protection: assignment type 1 assignment type 2 25 a 10 a connecting leads finely stranded with wire end fer- rules singlecore 2x (0.75 to 2.5) mm 2 2x (1 to 2.5) mm 2 1 x 4 mm 2 dimensions (wxhxd) 36 x 72 x 55 ambient temperature -25 ... +55 c storage temperature -50 ... +80 c technical data
225 logo! manual a5e00119092-01 b determining the cycle time the program cycle is the complete execution of the pro- gram, that is, primarily the reading in of the inputs, the processing of the program and the subsequent reading out of the outputs. the cycle time is the time required to exe- cute a program once in full. the time required for a program cycle can be determined using a short test program. this test program is generated in logo!. in parameter assignment mode it outputs a value used to calculate the actual cycle time. test program 1. start to create the test program by linking an output or memory bit to a threshold switch. at the input of the switch you can then connect a clock generator that is switched on with a hi signal. hi par qx t b02 b01 output q or memory bit m 2. configure the two blocks as shown below. due to the pulse rate of a 0 seconds a pulse is generated in every program cycle. the time interval of the threshold switch is set to 2 seconds. b02:t t =00.00s+ b01:par sw =1000+ sw =0000 g_t=02.00s  
logo! manual a5e00119092-01 226 3. then start the program and switch the logo! to pa- rameter assignment mode. you can view the parame- ters of the threshold switch in this parameter assign- ment mode. b01:par sw =1000+ sw =0000 fa =0086   fa= is the sum of the pulses measured per time unit g_t 4. the reciprocal value of fe is equal to the cycle time of the logo! with the program currently in its memory. 1/fe = cycle time in s explanation the output signal of the clock pulse generator (t=0) is toggled at every program cycle. thus, one logic level (high or low) width is exactly equivalent to the length of one cycle. hence, a period lasts 2 cycles. the threshold switch indicates the ratio of periods per 2 seconds which results in the ratio of cycles per second. edge change of the clock generator art every program cycle cycle time periods 1 period = 1 pulse = 2 cycles determine the cycle time
227 logo! manual a5e00119092-01 c logo! without display the logo! version without display is intended for use in specific applications not requiring operating elements such as a keyboard or a display 12/24 rco, logo! 24 rco and logo! 230 rco. for example, this is what a logo! 230 rco looks like: i4 i5 i6 q1 q2 q3 q4 l1 n run/stop i7 i8 i1 i2 i3 i1 i2 i3 i1 i2 i3 i1 i2 i3 i1 i2 i3 i1 i2 i3 i1 i2 i3 i1 i2 i3 1 2 1 2 1 2 1 2 less is definitely more! your benefits:  improved economies without the operating element.  requires less switch cabinet space than conventional hardware.  substantial benefits with regard to flexibility and prime costs compared to standalone electronic switchgear.  of advantage even for applications in which merely two or three conventional switching devices can be re- placed.  very easy to use.  cannot be used by unauthorized persons.  compatible with logo! basic variants.  offers the option to read data via logo!soft comfort,
logo! manual a5e00119092-01 228 programming without an operating element you can program the logo! without display in two ways:  on the pc, create a program with logo!soft comfort and transfer it to the logo!  use a logo! program module/card and transfer the program contained in this device to the logo! without display operating characteristics the logo! is ready for operation when power is switched on. switching off a logo! without display is equivalent to disconnecting the power supply, e.g. as if you remove the plug. logo! rco versions cannot be prepared for data transfer per keyboard and the programs cannot be started or stopped per pushbutton. this is why the startup behavior of logo! rco versions has been slightly modified: startup characteristics the program in a module/card that is plugged into the logo! is copied immediately to the logo! after power is switched on. an existing program is overwritten. if a pc cable is connected the logo! switches automati- cally to pc
logo mode at startup. the pc software logo!soft comfort can be used to read the program of the logo! or to save them to the logo!, after power is switched on, the logo! automatically switches from stop to run if a valid program exists in memory. logo! without display
229 logo! manual a5e00119092-01 operating status indicator operating states, e.g. power on, run and stop are indi- cated by an led on the front hood.  red led: power on/stop  green led: power on/run the red led is lit after power on and in all logo! states other than run. the green led is lit when logo! is in run mode. reading the operating hours counter in stop mode prerequisites: the pc link must be plugged in prior to power on. in logo!soft comfort as of v 3.0 (refer to chapter 7) you can read the mn and ot values of the hours counter. the hours counter values can be fetched without having to en- ter a password. if your logo! without display is equipped with a red mod- ule you cannot fetch the values of the hours counter, be- cause when you remove the module (in order to connect the pc link) you delete the program in the logo!. . logo! without display
logo! manual a5e00119092-01 230 logo! without display
231 logo! manual a5e00119092-01 d logo! menu structure >program.. >pc/card.. > password >clear prg >edit prg abc q1 > card-> ->card > pc<-> > prg name password? aa old: no password new:  clear prg > no yes q1 > pc<-> stop? press esc if no module/card is inserted logo! returns to the main menu. the program is transferred. main menu programming menu transfer menu
logo! manual a5e00119092-01 232 > clock.. >start >set clock > s/w time set clock > on off th 14: 45 mm.dd.yy 06. 21. 01 s/w time: off > eu uk us .. eu uk us > .. mm.dd + : 0 3. 3 1 d = 120 min : 1 1. 0 1 th 14: 45 06. 21. 01 i:0.,1.,2. 123456789 0123456789 01234 q:0.,1. 123456789 0123456 keys keys n times message text n = 0. . 5 n times message text n = 0. . 5 n times message text n = 0. . 5 >stop set param set clock prg name parameter assignment menu logo! menu structure
233 logo! manual a5e00119092-01 >stop > prg name parameter assignment menu stop prg > no yes >set param b05 : par sw :0050 sw :0048 fe = 0012 >set clock set clock th 14: 45 mm.dd.yy 06. 21. 01 stop prg no > yes program.. pc/card.. clock.. start main menu abc no program press esc no program after power on program.. pc/card.. clock.. start main menu th 14: 45 06. 21. 01 i:0.,1.,2. 123456789 0123456789 01234 q:0.,1. 123456789 0123456 or or logo! menu structure
logo! manual a5e00119092-01 234 logo! menu structure
235 logo! manual a5e00119092-01 order numbers table a variant designation order number basic logo! 12/24 rc * logo! 24): logo! 24 rc (ac) logo! 230 rc 6ed1 0521md000ba3 6ed1 0521cc000ba3 6ed1 0521hb000ba3 6ed1 0521fb000ba3 basic without display logo! 12/24 rco * logo! 24 rco (ac) logo! 230 rco 6ed1 0522md000ba3 6ed1 0522hb000ba3 6ed1 0522fb000ba3 digital module logo! dm8 12/24r logo! dm8 24 logo! dm8 230r 6ed1 0551mb000ba0 6ed1 0551cc000ba0 6ed1 0551fb000ba0 analog module logo! am2 6ed1 0551ma000ba0 *: also with analog inputs
logo! manual a5e00119092-01 236 table b accessories designation order number software logo!soft comfort v3.0 upgrade comfort v1.0, v2.0 to v3.0 6ed1 0580ba000yc2 6ed1 0580ca000yc1 program mod- ules yellow card red card 6ed1 0561ba000aa0 6ed1 0564ba000aa0 switching mod- ule logo!contact 24 v logo!contact 230 v 6ed1 0574ca000aa0 6ed1 0574ea000aa0 power modules logo!power 12v/1.9a logo!power 12v/4.5a logo!power 24v/1.3a logo!power 24v/2.5a 6ep1 3211sh01 6ep1 3221sh01 6ep1 3311sh01 6ep1 3321sh41 others pc cable manual 6ed1 0571aa000ba0 6ed1 0501aa000be4 order numbers
237 logo! manual a5e00119092-01 abbreviations am analog module b01 block number b01 bn block number c in the logo! device designation: integrated clock cnt count = input for counter co connector dir direction (e.g. for counter) dm digital module en enable (e.g. for switching on the clock pulse generator) bf basic functions no cams (time switch parameters) o in the logo! device designation: without display par parameter r reset r in the logo! device designation: relay outputs s set (e.g. setting the latching relay) sf special functions t time (parameter) s segment trg trigger (parameter) 0ba3 devices: the latest logo! basic version, described in this manual.
logo! manual a5e00119092-01 238
239 logo! manual a5e00119092-01 index symbols ?, on the display, 71 a analog comparator, 138 values, 96 analog module, 2, 7 and, 87 and , 87 and not, 88 applications, 171 as interface, 2 as interface, 7, 192 as interface function module, 192 asynchronous pulse generator, 130 b basic functions, 85 and, 87 with edge, 87 nand, 88 with edge, 89 nor, 90 not, 91 or, 89 xor, 91 basics on special functions, 92 bf, 81, 85 block, 39 deleting, 69 interconnected blocks, 70 inserting, 64 number, 39 assigning, 40 block diagram, 41 bn, 81 c ce marking, 9 certification , 9 character set, 56 checking , 67 circuit diagram, 42 circuit program , 77 circuit status transition, 25 clock generator, symmetric, 128 co, 81, 82 compatibility, versions, 160 connecting, inputs, 24 connection, x, 93 connector, 16
logo! manual a5e00119092-01 240 connectors, 36, 82, 84 hi, 38 inputs, 38 lo, 38 logo!'s, 38 outputs, 38 x, 38 connectors , 82 constants , 82 control panel, 4, 5 conversion, summertime and wintertime, 73 correcting typing errors, 71 counter operating hours, 124 up/down, 122 cover, 16 csa, 9 cursor, 46 cursor movement, 46 cycle time, 225 d demo versions, 168 digital module, 2, 7 dimensions, 15 display, 40 display view, 40 displaying, 67 drag&drop, 168 e edge evaluation, 89 edge triggering, 87 editing, 64 equipment types, logo!, 2 example airconditioning system, 183 automatic door, 176 further applications, 204 industrial gate, 188 industrial gate controlling, 192 monitoring, 192 lighting corridor, 172 staircase, 172 luminous rows, 196 service water pump, 200 exclusive or, 91 exiting programming mode, 68 expansion module, analog mo- dule, 38 expansion module , digital mo- dule, 38 expansion modules, 2 analog module, 2 communication module, 2 digital module, 2 operating state, 34 expansion modules, 36 index
241 logo! manual a5e00119092-01 f fm approval, 9 four golden rules, 45 frequency functions, 26 function blocks, 39 function module asi, 2 function moduleasi, 7 functions, 81 g gain, 96 golden rules, 45 ground terminal, 23 guidelines, 11 h hiding, 67 i initialization memory bit, 83 inputs, 82 analog inputs, 26, 82 connection, 24 digital inputs, 82 fast inputs, 26 groups, 25 onscreen presentation, 61 inserting, 64 internet address, 171 inverter, 91 l latching relay, 109 lcd, 4, 5 led, 229 levels, 84 limit, 77 list bf, 81 bn, 81 co, 81, 82 sf, 81, 98 list , bf, 85 logic module, 1 logical inputs, 93 logo! connecting to pc, 169 guidelines, 11 installing, 15 operating states, 34 recognizing, 7 structure of, 4 switching on, 31 uninstalling, 15 variants, 8 wiring, 22 index
logo! manual a5e00119092-01 242 logo! menus, 47 logo! software, 167 logo!soft comfort, 168 m memory area, 77 space, 77 utilization, 78 memory bits, 83 menu structure, 231 menus main menu, 47 menu clock, 47 parameter assignment menu, 47 programming menu, 47 transfer menu, 47 message texts, 145 message texts, character set, 147 mode parameter assignment, 152 parameter assignment, 47 programming, 47 mounting drilling template, 21 profile rail mounting, 16 wallmounting, 20 mounting guidelines, 11 multifunctional switch, 143 n name, 55 nand, 88 negation, 91 nor , 90 not , 91 o off delay, 103 offtime, 117 offset, 96 on delay, 101 retentive, 107 ontime, 117 on/off delay, 105 open connectors, 84 operating characteristics, 228 hours counter, fetching mn and ot values, 229 status indicator, 229 operating hours counter, 124 hours counter, reading mn and ot values, 126 index
243 logo! manual a5e00119092-01 operating mode changing operating mode, 45 programming mode, 48 or, 89 or , 89 or not, 90 output connection, connecting, 29 outputs, 82 connecting, 29 presentation on the display, 61 p par, 77 parameter, 153 'set param', 153 displaying/hiding, 67 inputs, 94 selecting, 154 setting, 151 t, 9 4 parameter assignment, 66 parameter assignment menu, 152 parameter assignment screen form, 116, 146 parameter protection, 96 parameters, changing, 155 password assigning, 57 changing, 58 deactivating, 59 wrong input, 60 pc logo, 169 pc logo mode, 169 pc cable, 169 planning, 46 power off, 32 on, 32 return, 31 switch, 31 power supply, connecting, 22 prewarning duration , 142 prewarning time , 142 profile rail, 15 program cycle, 225 program module 'card > logo', 166 'logo > card', 163 copying, 165 inserting, 161, 162 red, 159 removing, 161, 162 yellow, 159 program name assigning, 55 changing, 56 character set, 56 read, 153 index
logo! manual a5e00119092-01 244 programs 'clear prg', 72 'edit prg', 49 'password', 57 'prg name', 55 archiving, 159 changing, 63 deleting, 72 duplicating, 159 editing, 51 sending by post, 159 pulse pause, 130 width , 130 pulse generator, asynchronous , 130 pulse output, 112 pulse relay, 111 r ram, 77 random generator, 131 relay outputs, 29, 219 service life, 219 switching capacity, 219 rem, 77 resources, 77 retentive on delay, 107 retentivity, 95 rules, four golden, 45 run, 'start', 61 s sensor attributes, 24 sensor connections, 27 set clock, 'set clock', 158 setting, 66 setting the date, 158 setting the timeofday, 'set clock', 153 setting the timeofday, 158 sf, 81, 98 simulation , 167 size of a circuit, 77 slide, 17, 19 softkey, 148 software , 167 index
245 logo! manual a5e00119092-01 special functions, 98 analog comparator, 138 basic knowledge, 92 clock generator, symmetric, 128 counter hours counter, 124 up/down, 122 delay delay, 103 on, 101 on/off, 105 retentive on, 107 message texts, 145 pulse generator, asynchro- nous, 130 random generator, 131 relay lock, 109 pulse, 111 softkey, 148 switch comfort, 143 stairway lighting, 141 threshold switch, frequency, 133 threshold switch, analog, 135 timer, week, 115 timer switch, year, 120 wiping relay, pulse output, 112 wiping relay, edgetriggered, 114 stairway lighting switch, 141 start, 61 startup characteristics, 228 stop, 152 structure, 13 maximum structure, 13 with different voltage classes, 14 summertime, 73 summertime/wintertime con- version, 73 's/w time', 73 customizing parameters, 75 enable, 76 enabling, 73 switch comfort, 143 stairway lighting, 141 switched current, maximum, 30 symbols, 7 symmetric clock generator, 128 t t. see time technical data, 207 general, 207 logo! 12..., 215 logo! 230...., 209 logo! 24, 212 logo! am2, 218 logo! dm8 12/24r, 215 logo! dm8 230r, 209 logo! dm8 24, 212 logo!contact, 224 logo!power 12 v, 220 logo!power 24 v, 222 index
logo! manual a5e00119092-01 246 threshold switch analog, 135 frequencies, 133 time, accuracy of, 95 time, accuracy of, 143 time response, 94 time switch, 1 timer, 77 timer switch, accuracy, 95 timing deviation , 95 transistor outputs, 30 type of equipment, logo!, 2 type of protection, 67 u ul, 9 uninstalling, 18 unit segments, 15 up/down counter, 122 upgrade, 168 upward compatibility, 161 v voltage levels , 84 voltage supply, connecting, protective circuit, 23 w weekday, 116 weekly timer switch, 7, 117 examples, 118 setting, 117 weekly timer switch , 115 wintertime, 73 wiping relay edge triggered, 114 pulse output, 112 wire ferrules, 22 without display, 227 reading the operating hours counter, 229 x xor , 91 y yearly timer switch, 120 z zero point, 96 index


▲Up To Search▲   

 
Price & Availability of 6ED1052-1HB00-0BA3

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X